Clinical impact of antithrombotic therapy in transvenous lead extraction complications: a sub-analysis from the ESC-EORP EHRA ELECTRa (European Lead Extraction ConTRolled) Registry.
Аннотация
AIMS: A sub-analysis of the ESC-EHRA European Lead Extraction ConTRolled (ELECTRa) Registry to evaluate the clinical impact of antithrombotic (AT) on transvenous lead extraction (TLE) safety and efficacy.
METHODS AND
RESULTS
ELECTRa outcomes were compared between patients without AT therapy (No AT Group) and with different pre-operative AT regimens, including antiplatelets (AP), anticoagulants (AC), or both (AP + AC). Out of 3510 pts, 2398 (68%) were under AT pre-operatively. AT patients were older with more comorbidities (P < 0.0001). AT subgroups, defined as AP, AC, or AP + AC, were 1096 (31.2%), 985 (28%), and 317 (9%), respectively. Regarding AP patients, 1413 (40%) were under AP, 1292 (91%) with a single AP, interrupted in 26% about 3.8 ± 3.7 days before TLE. In total, 1302 (37%) patients were under AC, 881 vitamin K antagonist (68%), 221 (17%) direct oral anticoagulants, 155 (12%) low weight molecular heparin, and 45 (3.5%) unfractionated heparin. AC was 'interrupted without bridging' in 696 (54%) and 'interrupted with bridging' in 504 (39%) about 3.3 ± 2.3 days before TLE, and 'continued' in 87 (7%). TLE success rate was high in all subgroups. Only overall in-hospital death (1.4%), but not the procedure-related one, was higher in the AT subgroups (P = 0.0500). Age >65 years and New York Heart Association Class III/IV, but not AT regimens, were independent predictors of death for any cause. Haematomas were more frequent in AT subgroups, especially in AC 'continued' (P = 0.025), whereas pulmonary embolism in the No-AT (P < 0.01).
CONCLUSIONS
AT minimization is safe in patients undergoing TLE. AT does not seem to predict death but identifies a subset of fragile patients with a worse in-hospital TLE outcome.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.