MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3109/00016489309135896

Медицинская библиотека · Acta oto-laryngologica · 1993

Fine structure of the tendon of the human stapedius muscle: comparison of normals and clinically otosclerotic patients.

Franz P, Böck P, Swoboda H, Türk R, Grasl M C, Aharinejad S, Firbas W

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

The tendon of the human stapedius muscle was studied in normal post mortem material and in clinical otosclerotic patients, using light and electron microscopy. Cross section profiles of collagen fibrils were measured in various regions of the tendon and the amount of elastin was estimated. The normal stapedius tendon consisted of three concentrically arranged portions: A cylindrical central part, a tube-like mid-portion, and a cortical layer. The central part was made up of collagen fibrils with only a few elastic fibers, the mid-portion contained collagen fibrils together with significantly more elastic material, while the cortical layer, again, showed a smaller amount of elastic fibers. Mean diameters of collagen fibrils in the central part of the tendon were 65.12 +/- 11.89 nm, in the intermediate layer 41.00 +/- 9.63 nm, and in the cortical layer 70.28 +/- 19.58 nm. Stapedius tendons from clinically otosclerotic patients, though showing the same construction, were characterized by significantly altered collagen fibrillar diameters (Mann-Whitney U-test). In the central part, mean diameters were reduced to 61.05 +/- 14.70 nm, in the mid-portion increased to 50.90 +/- 10.08 nm, and in the cortical layer reduced to 61.09 +/- 8.49 nm. The changes of collagen cross section profiles estimated for the entire tendon were significant as well: 59.68 +/- 18.74 nm in controls versus 57.82 +/- 12.53 nm in otosclerotic patients. Elastin content in the mid-portion of control stapedius tendons increased with age (13% at 35 years of age to 35% at 70 years of age).(ABSTRACT TRUNCATED AT 250 WORDS)

Для цитирования: Franz P, Böck P, Swoboda H, Türk R, Grasl M C, Aharinejad S, Firbas W. Fine structure of the tendon of the human stapedius muscle: comparison of normals and clinically otosclerotic patients.. Acta oto-laryngologica. 1993. DOI: 10.3109/00016489309135896.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.