DOI 10.1016/j.heares.2024.109167
Auditory working memory in noise in cochlear implant users: Insights from behavioural and neuronal measures.
Аннотация
OBJECTIVE
We investigated auditory working-memory using behavioural measures and electroencephalography (EEG) in adult Cochlear Implant (CI) users with varying degrees of CI performance.
METHODS
24 adult CI listeners (age: M = 61.38, SD = 12.45) performed the Sternberg auditory-digit-in-working-memory task during which EEG, accuracy, and promptness were captured. Participants were presented with 2, 4, or 6 digits at Signal-to-Noise Ratios (SNR) of 0, +5 and +10dB. They had to identify a probe stimulus as present in the preceding sequence. ANOVA models were used to compare conditions.
RESULTS
ANOVA revealed that increasing memory load (ML) led to decreased task performance and CI performance interacted with ML and SNR. Centro-parietal alpha power increased during memory encoding but did not differ between conditions. Frontal alpha power was positively correlated with accuracy in conditions most affected by SNR (r = 0.57, r = 0.52) and theta power in conditions most affected by ML (r = 0.55, r = 0.57).
CONCLUSIONS
While parietal alpha power is modulated by the task, it is frontal alpha that relates quantitatively to sensory aspects of processing (noise) and frontal theta to memory load in this group of CI listeners.
SIGNIFICANCE: These results suggest that alpha and theta show distinct relationships to behaviour, providing additional insight into neurocognitive (auditory working-memory) processes in CI users.