MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11060-026-05729-7

Медицинская библиотека · Journal of neuro-oncology · 2026

Dosimetric and spatial impact of high-resolution SPACE MRI on target delineation for glomus tumor radiosurgery: a retrospective cohort study.

Thimmarayappa Arun, Beniwal Manish, Saini Jitender, Sadashiva Nishanth, Konar Subhas Kanti, Srinivas Dwarkanath, Arimappamagan Arivazhagan, Vazhayil Vikas, Andiperumal Raj Prabhuraj, Shashidhar Abhinith, Deora Harsh, Birua Gyani Jail Singh, Govindarajan Nandakarthik, Balakrishnan Jeeva, Natesan Ponnusamy

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate sequence-dependent volumetric, spatial, and dosimetric discrepancies between standard T1c gradient-recalled echo and high-resolution T1c turbo spin-echo (SPACE) sequences for stereotactic radiosurgery of glomus jugulare tumors.

METHODS

We retrospectively analyzed 47 patients undergoing Gamma Knife radiosurgery for glomus tumors. Pre-treatment 1.5T MRI included T1c MPRAGE and T1c SPACE sequences acquired during a single session. Gross tumor volumes (GTV) were delineated by multidisciplinary consensus. Geometric variances were quantified using the Dice Similarity Coefficient (DSC) and 95% Hausdorff Distance (HD95). A three-phase dosimetric analysis evaluated the clinical T1c-optimized plan, the hypothetical target coverage (V100%) variance when applying the unchanged T1c plan to the SPACE target, and a corrective SPACE-optimized research replan.

RESULTS

Median SPACE-derived GTVs (10.67 cm³) were significantly larger than T1c-derived GTVs (9.51 cm³, p < 0.001). Volumetric expansion occurred predominantly at the peripheral tumor-vessel interface. The median DSC was 0.917 and HD95 was 1.89 mm. Applying clinical T1c plans to SPACE targets produced a sequence-dependent geographic discrepancy, reducing hypothetical V100% coverage from 95.6% to 91.0% (p < 0.001). Corrective replanning with SPACE targets restored coverage while significantly lowering brainstem and cochlear organ-at-risk doses (p < 0.001), though this may partially reflect retrospective optimization bias.

CONCLUSION

MRI sequence selection fundamentally alters GTV delineation and dosimetric parameters in glomus radiosurgery. Flow-suppressed SPACE sequences consistently yield larger target volumes at the complex tumor-vessel interface, mathematically reducing target coverage against conventional T1c planning. Lacking a definitive pathological benchmark, the true clinical significance of these specific contour discrepancies requires prospective oncological validation.

Для цитирования: Thimmarayappa Arun, Beniwal Manish, Saini Jitender, Sadashiva Nishanth, Konar Subhas Kanti, Srinivas Dwarkanath, Arimappamagan Arivazhagan, Vazhayil Vikas, Andiperumal Raj Prabhuraj, Shashidhar Abhinith, Deora Harsh, Birua Gyani Jail Singh, Govindarajan Nandakarthik, Balakrishnan Jeeva, Natesan Ponnusamy. Dosimetric and spatial impact of high-resolution SPACE MRI on target delineation for glomus tumor radiosurgery: a retrospective cohort study.. Journal of neuro-oncology. 2026. DOI: 10.1007/s11060-026-05729-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.