Retrieval transfusion protocol in New South Wales, Australia: A retrospective review of the first 5 years.
Аннотация
BACKGROUND
Ambulance service blood transfusion is an area of rapid development. In New South Wales, Australia, the blood products carried by ambulance medical teams are often the first available to patients with critical bleeding. In addition to the blood products routinely carried by these teams, the Service created and implemented a method of initiating large-volume, mixed-product transfusions using existing blood banks: the Retrieval Transfusion Procedure (RTP). This article describes the trends and characteristics of New South Wales Ambulance RTP activations.
MATERIALS AND
METHODS
This retrospective database review examines the patient records for all RTP activations. Key areas of investigation include logistics, product requests, population demographics, etiologies, physiology, mission timings, and transfusions.
RESULTS
Ambulance medical teams attended 27 531 missions in the reviewed period, 1573 patients received transfusion, and there were 138 RTP activations. Blood products were sourced from 40 banks and transported by police (46.7%), ambulance (27.1%), and helicopter (13.0%) to refueling stops (39.2%), prehospital scenes (24.2%) and hospitals (15.8%). The median time engaged on each mission was 189 minutes for metropolitan and 222 minutes for rural locations. Seventy-eight patients were transfused with RTP blood products; 83.3% were traumas, of which 63.1% were motor vehicle collisions. Up to 18 units of blood products were administered before hospital arrival. There was significant (P < .001) improvement in the mean shock index of transfused patients between the first and final observations recorded.
CONCLUSIONS
Ambulance service extended blood product transfusion is logistically achievable and facilitates emergency transfusions throughout the state with minimal additional infrastructure.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.