m+Medelevator.RU
← Поиск публикаций
Esophagus : official journal of the Japan Esophageal Society · 2025

Comparison of anastomotic stricture rates between 23- and 25-mm powered circular staplers in cervical esophagogastric anastomosis: a propensity-matched study.

СтатьяСравнительное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Saito Akira, Otsuka Koji, Goto Satoru, Ariyoshi Tomotake, Yamashita Takeshi, Motegi Kentaro, Komoto Masahiro, Kishimoto Yutaka, Murakami Masahiko, Aoki Takeshi

Аннотация

BACKGROUND: Circular stapler (CS) anastomosis is widely used in McKeown esophagectomy; however, anastomotic stenosis remains a significant concern. This study aimed to compare stenosis rates between newly introduced 23- and 25-mm powered CSs in cervical esophagogastric anastomosis.

METHODS: From May 2022 to February 2024, 126 patients who underwent thoracoscopic McKeown esophagectomy with retrosternal gastric conduit reconstruction were retrospectively analyzed. They were categorized into the 23-mm (n = 52) and 25-mm (n = 74) CS groups. The primary endpoint was the comparison of anastomotic stricture rates. Propensity score matching was performed to adjust for potential confounders.

RESULTS: After propensity score matching, 39 pairs were selected. The incidence of anastomotic stricture was 18.0% (7 cases) and 12.8% (5 cases) in the 23- and 25-mm CS groups, respectively (p = not significant [NS]). The incidence of anastomotic leakage and the leakage location revealed no significant differences between the two groups. A two one-sided test for equivalence was performed to compare the risk difference in stricture rates between the groups, resulting in a risk difference of 5.1% with a 90% confidence interval of - 0.087 to 0.191 and a p value of 0.041, suggesting potential equivalence.

CONCLUSION: In this study, 23- and 25-mm powered CSs achieved comparable anastomotic stricture rates in cervical esophagogastric anastomosis during McKeown esophagectomy. The newly introduced 23-mm powered CS can be a useful option, considering its easier anvil insertion into the residual esophagus when insertion of the 25-mm CS anvil is technically challenging.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты