Медицинская библиотека · RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin · 2003

[Quality rating of MR-cholangiopancreatography with oral application of iron oxide particles].

Lorenzen M, Wedegärtner U, Fiehler J, Adam G

Клиническое исследованиеСравнительное исследованиеАннотация на английскомСтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To compare image quality in magnetic resonance cholangiopancreatography (MRCP) performed with and without oral application of Lösferron (ferrous gluconate, Lilly Pharma, Hamburg).

MATERIALS AND

METHODS

A prospective study compares MRCPs performed on 52 patients with a 1.5 T clinical whole body scanner using a standard body coil. After randomization, patients ingested either 0.5 l of Lösferron (n = 27, group 1) or no oral contrast agent (n = 25, group 2) prior to the examination. 7 RARE (40 to 20 degrees) sequences were obtained, followed by selected 3 mm HASTE (T 2 -weighted with fat suppression) sequences. After blinding, image quality was rated by two radiologists using a scale of 1 (not discernible) to 5 (very well discernible). The following sections of the biliary ductal system were evaluated: left and right hepatic duct, extrahepatic bile duct and intrapancreatic bile duct. The pancreatic duct was evaluated by its location: head, body and tail of the pancreas. A Wilcoxon-Mann-Whitney test was used to determine significant differences (p < 0.05) between sampled ductal segments. Correction for multiple testing was applied.

RESULTS

The oral application of Lösferron was well tolerated by all patients, and all sequences could be acquired and evaluated in all 52 patients. For the different sections of the biliary system, the mean ratings with and without Lösferron were, respectively, 3.28 and 3.36 for the left hepatic duct, 3.26 and 3.33 for the right hepatic duct, 3.46 and 4.0 for the extrahepatic bile duct, and 2.8 and 3.48 for the intrapancreatic bile duct. The corresponding ratings for the pancreatic duct were 2.8 and 3.24 for the pancreatic head, 2.84 and 3.38 for the pancreatic body, and 2.68 and 3.22 for the pancreatic tail. The differences with and without contrast agent were not statistically significant. Interobserver variability was between 0.37 for the pancreatic duct in the tail of the pancreas and 0.66 for the right hepatic duct.

CONCLUSION

Despite the trend toward a better rating of the image quality for all sections of the pancreaticobiliary ductal system with Lösferron, a significant difference was not found in any ductal section after correction for multiple testing. Thus, we believe that the ingestion of Lösferron is not absolutely required prior MRCP.

Для цитирования: Lorenzen M, Wedegärtner U, Fiehler J, Adam G. [Quality rating of MR-cholangiopancreatography with oral application of iron oxide particles].. RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin. 2003. DOI: 10.1055/s-2003-40439.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.