MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jpeds.2010.06.012

Медицинская библиотека · The Journal of pediatrics · 2010

Outcomes and causes of death in children on home mechanical ventilation via tracheostomy: an institutional and literature review.

Edwards Jeffrey D, Kun Sheila S, Keens Thomas G

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

To describe outcomes and causes of death in children on chronic positive-pressure ventilation via tracheostomy.

STUDY

DESIGN

We conducted a retrospective observational cohort analysis of 228 children enrolled in an university-affiliated home mechanical ventilation (HMV) program over 22 years (990 person-years). Cumulative incidences of survival and liberation from HMV are presented. Time-to-events were compared by reason for chronic respiratory failure (CRF) and age and date of HMV initiation with Kaplan-Meier and Cox regression analyses. Circumstances of death are described.

RESULTS

Of our cohort, 47 of 228 children died, and 41 children were liberated from HMV. The 5-year cumulative incidences of survival and liberation were 80% and 24%, respectively. Being placed on HMV for chronic pulmonary disease was independently associated with liberation from HMV (hazard ratio, 7.38; 95% CI, 3.0-18.2; P < .001). Neither age nor reasons for CRF were associated with shortened survival. Progression of underlying condition accounted for only 34% of deaths; 49% of deaths were unexpected.

CONCLUSION

Most children on HMV survive or were weaned off. However, a sizable number of children in our cohort died, and many deaths were unexpected and from causes not directly related to their primary reason for CRF.

Для цитирования: Edwards Jeffrey D, Kun Sheila S, Keens Thomas G. Outcomes and causes of death in children on home mechanical ventilation via tracheostomy: an institutional and literature review.. The Journal of pediatrics. 2010. DOI: 10.1016/j.jpeds.2010.06.012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.