Dark-blood late gadolinium enhancement CMR improves detection of papillary muscle fibrosis in patients with mitral valve prolapse.

Van De Heyning Caroline M, Holtackers Robert J, Nazir Muhummad Sohaib, Grapsa Julia, Demetrescu Camelia, Pype Lobke, Chiribiri Amedeo

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Papillary muscle fibrosis may act as an arrhythmogenic substrate in patients with mitral valve prolapse (MVP). Previous studies used conventional bright-blood late gadolinium enhancement cardiovascular magnetic resonance (LGE CMR) imaging to assess papillary muscle fibrosis, although this technique suffers from poor scar-to-blood contrast which may limit its sensitivity, in contrast to dark-blood LGE. This study sought to compare bright-blood and dark-blood LGE for the detection of papillary muscle fibrosis in patients with MVP.

METHOD: 60 patients with known isolated MVP referred for CMR were prospectively recruited. A routine CMR protocol was used to obtain cine imaging, dark-blood LGE and bright-blood LGE in three long-axis views and a stack of short-axis views. Flow mapping of the proximal aorta was performed to calculate mitral regurgitant volume. Images were analysed for cardiac volumes, ejection fraction, mitral regurgitation severity, MVP characteristics (mitral annular disjunction, prolapse volume) and presence of LGE at the papillary muscles and myocardium.

RESULTS

Dark-blood LGE detected significantly more subjects with LGE at the papillary muscles than bright-blood LGE (35% vs 15%, p = 0.002). There was no difference between LGE techniques regarding myocardial (non-papillary muscle) fibrosis (present in 25% each). No statistical differences were observed between patients with or without LGE at the papillary muscles regarding demographics, clinical data (including ventricular arrhythmia) and MVP characteristics. Furthermore, no association was found between LGE at the papillary muscles and at the myocardium.

CONCLUSIONS

Compared to bright-blood LGE, dark-blood LGE CMR improves the detection of LGE at the papillary muscles in patients with MVP.

Для цитирования: Van De Heyning Caroline M, Holtackers Robert J, Nazir Muhummad Sohaib, Grapsa Julia, Demetrescu Camelia, Pype Lobke, Chiribiri Amedeo. Dark-blood late gadolinium enhancement CMR improves detection of papillary muscle fibrosis in patients with mitral valve prolapse.. European journal of radiology. 2021. DOI: 10.1016/j.ejrad.2021.110118.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.