International journal of dermatology · 2013
Treatment of nevus of Ota using low fluence Q-switched Nd:YAG laser.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Choi Chong Won, Kim Hee Jung, Lee Heun Joo, Kim Yoon Hwan, Kim Won-Serk
Аннотация
BACKGROUND: Nevus of Ota, caused by dermal melanocytosis, is cosmetically troublesome in Asian patients. The destruction of dermal melanocytosis using Q-switched laser systems carries a high risk of postinflammatory hyperpigmentation/hypopigmentation.
METHODS: To determine the usefulness, safety, and adverse problems of low fluence 1064 nm Q-switched Nd:YAG laser in the treatment of nevus of Ota, 19 Korean patients (five male and 14 female; Fitzpatrick skin type IV) who were clinically diagnosed as having nevus of Ota were enrolled in the present study. Low fluence laser treatments were performed with a collimated Q-switched Nd:YAG laser at intervals of two weeks. The fluence of laser treatments was set at 2.5 J/cm(2) and adjusted based on patient response to the previous treatment session and sensitivity to pain. Treatment was applied until the lesions showed mild erythema.
RESULTS: The mean number of total treatment sessions was 17.1 (range 6-32). Among the 19 patients, 18 reached near total improvement, while one patient failed to reach near total improvement after 11 treatment sessions. The mean fluence of treatment was 2.5 J/cm(2) (range 2.0-5.0 J/cm(2) ). Five patients complained of delayed eyelid response. Post-therapy hyperpigmentation was observed in one patient.
CONCLUSION: Low fluence 1064 nm Q-switched Nd:YAG laser is an effective modality for the treatment of nevus of Ota with a low incidence of side effects. It is an easy to perform treatment with low downtime.
METHODS: To determine the usefulness, safety, and adverse problems of low fluence 1064 nm Q-switched Nd:YAG laser in the treatment of nevus of Ota, 19 Korean patients (five male and 14 female; Fitzpatrick skin type IV) who were clinically diagnosed as having nevus of Ota were enrolled in the present study. Low fluence laser treatments were performed with a collimated Q-switched Nd:YAG laser at intervals of two weeks. The fluence of laser treatments was set at 2.5 J/cm(2) and adjusted based on patient response to the previous treatment session and sensitivity to pain. Treatment was applied until the lesions showed mild erythema.
RESULTS: The mean number of total treatment sessions was 17.1 (range 6-32). Among the 19 patients, 18 reached near total improvement, while one patient failed to reach near total improvement after 11 treatment sessions. The mean fluence of treatment was 2.5 J/cm(2) (range 2.0-5.0 J/cm(2) ). Five patients complained of delayed eyelid response. Post-therapy hyperpigmentation was observed in one patient.
CONCLUSION: Low fluence 1064 nm Q-switched Nd:YAG laser is an effective modality for the treatment of nevus of Ota with a low incidence of side effects. It is an easy to perform treatment with low downtime.