OBJECTIVE

To study the efficacy of porous polyethylene (Medpor) plus titanic mesh sheets in the repair of orbital blowout fractures.

METHODS

A total of 20 patients underwent open surgical reduction with the combined usage of Medpor and titanic mesh. And they were followed up for average period of 14.5 months (range: 9 - 18).

RESULTS

There is no infection or extrusion of medpor and titanic mesh in follow-up periods. There was no instance of decreased visual acuity at post-operation. And all cases of enophthalmos were corrected. The post-operative protrusion degree of both eyes was almost identical at less than 2 mm. The movement of eye balls was satisfactory in all directions. Diplopia disappeared in 18 cases with a cure rate of 90%, 1 case improved and 1 case persisted.

CONCLUSION

Medpor plus titanic mesh implant is a safe and effective treatment in the repair of orbital blow out fractures.

Для цитирования: Han Xiao-hui, Zhang Jia-yu, Cai Jian-qiu, Shi Ming-guang. [Medpor plus titanic mesh implant in the repair of orbital blowout fractures].. Zhonghua yi xue za zhi. 2011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.