MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/lary.22376

Медицинская библиотека · The Laryngoscope · 2011

Clinically accurate assessment and grading of ototoxicity.

Chang Kay W

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES/HYPOTHESIS: To design a grading scale and audiologic protocols to better reflect clinical impact than the currently widely used classifications.

STUDY

DESIGN

Retrospective.

METHODS

Audiologic studies from 130 patients receiving cisplatin chemotherapy were analyzed. Pure-tone audiograms were evaluated using the newly proposed grading criteria, Brock criteria, and Common Terminology Criteria for Adverse Events (CTCAE). The resulting grades were then compared to recommended audiologic interventions. Auditory brainstem response (ABR) data and data on incidences of conductive hearing loss from other multi-institutional studies that the author participated in were compared to data from this cohort.

RESULTS

Although the newly proposed, Brock, and CTCAE ototoxicity grades were significantly related to audiologist recommendations for assistive devices (P < .0001), the newly proposed criteria were more specific and allowed better delineation of different patients into distinct subgroups requiring either FM system (grade 2a) or hearing aid (grade 2b or higher). Multi-institutional data review indicated significant problems with ABR evaluations and separating out conductive hearing losses from ototoxicity.

CONCLUSIONS

The newly proposed grading system needs to be paired with specific recommendations regarding audiologic monitoring protocols as well as active participation by the audiologists implementing the protocol to provide clinically accurate assessment and grading of ototoxicity.

Для цитирования: Chang Kay W. Clinically accurate assessment and grading of ototoxicity.. The Laryngoscope. 2011. DOI: 10.1002/lary.22376.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.