m+Medelevator.RU
← Поиск публикаций
Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology · 2010

Revision stapedotomy: operative findings and hearing results. A prospective study of 652 cases from the Otology-Neurotology Database.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Vincent Robert, Rovers Maroeska, Zingade Narayan, Oates John, Sperling Neil, Devèze Arnaud, Grolman Wilko

Аннотация

OBJECTIVE: To identify the causes of failure of primary stapes surgery and to evaluate the hearing results of revision stapes surgery in a consecutive series of 652 cases.

STUDY DESIGN: Prospective nonrandomized clinical study.

SETTING: Tertiary referral center.

PATIENTS: Six hundred thirty-four patients who underwent 652 consecutive revision stapes operations from April 1992 to December 2007 were enrolled in this study.

MAIN OUTCOME MEASURES: Preoperative and postoperative audiometric evaluation using conventional audiometry, namely, air-bone gap (ABG), bone-conduction thresholds, and air-conduction thresholds, were assessed. Postoperative audiometry was performed at 3, 6, 9, 12, 18, and 24 months and then annually for 15 years.

RESULTS: The most frequently identified reason for primary surgery failure was incus erosion (27.6%) and prosthesis displacement (18.2%). The postoperative ABG was closed to 10 dB or less and 20 dB or less in 63.4 and 74.6% of cases, respectively. The mean 4-frequency postoperative ABG was 11.5 dB as compared with 28 dB preoperatively (mean difference, 16.5 dB; 95% confidence interval [CI], 15.1-17.9 dB, p < 0.0001). The mean 4-frequency postoperative air-conduction thresholds were 45.7 dB compared with 58.7 dB preoperatively (mean difference, 13 dB; 95% CI, 11.4-14.6 dB, p < 0.0001). The mean 4-frequency postoperative bone-conduction thresholds were 34 dB compared with 30.6 dB preoperatively (mean difference, -3.5 dB; 95% CI, -4.4 to -2.5 dB, p < 0.0001). A significant postoperative sensorineural hearing loss (>15 dB) was observed in 2.9% of cases in this series.

CONCLUSION: Improvement of a conductive hearing loss after initial unsuccessful primary or revision stapes surgery can be accomplished with further revision but is occasionally modest.