MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/mao.0000000000004199

Медицинская библиотека · Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology · 2024

A Randomized Crossover Study in Single-Sided Deafness Comparing a Cartilage Conduction CROS System and an Air-Conduction CROS System.

Takaki Ken, Kashio Akinori, Nozaki Etsushi, Kanai Tomomi, Kamogashira Teru, Saze Fumikazu, Uranaka Tsukasa, Urata Shinji, Koyama Hajime, Kawahara Yoshihiro, Yamasoba Tatsuya

СтатьяРандомизированное исследованиеСравнительное исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVE

To investigate if cartilage conduction (CC) rerouting devices are noninferior to air-conduction (AC) rerouting devices for single-sided deafness (SSD) patients by measuring objective and subjective performance using speech-in-noise tests that resemble a realistic hearing environment, sound localization tests, and standardized questionnaires.

STUDY

DESIGN

Prospective, single-subject randomized, crossover study.

SETTING

Anechoic room inside a university.

PATIENTS: Nine adults between 21 and 58 years of age with severe or profound unilateral sensorineural hearing loss.

INTERVENTIONS: Patients' baseline hearing was assessed; they then used both the cartilage conduction contralateral routing of signals device (CC-CROS) and an air-conduction CROS hearing aid (AC-CROS). Patients wore each device for 2 weeks in a randomly assigned order.

MAIN OUTCOME MEASURES: Three main outcome measures were 1) speech-in-noise tests, measuring speech reception thresholds; 2) proportion of correct sound localization responses; and 3) scores on the questionnaires, "Abbreviated Profile of Hearing Aid Benefit" (APHAB) and "Speech, Spatial, and Qualities of Hearing Scale" with 12 questions (SSQ-12).

RESULTS

Speech reception threshold improved significantly when noise was ambient, and speech was presented from the front or the poor-ear side with both CC-CROS and AC-CROS. When speech was delivered from the better-ear side, AC-CROS significantly improved performance, whereas CC-CROS had no significant effect. Both devices mainly worsened sound localization, whereas the APHAB and SSQ-12 scores showed benefits.

CONCLUSION

CC-CROS has noninferior hearing-in-noise performance except when the speech was presented to the better ear under ambient noise. Subjective measures showed that the patients realized the effectiveness of both devices.

Для цитирования: Takaki Ken, Kashio Akinori, Nozaki Etsushi, Kanai Tomomi, Kamogashira Teru, Saze Fumikazu, Uranaka Tsukasa, Urata Shinji, Koyama Hajime, Kawahara Yoshihiro, Yamasoba Tatsuya. A Randomized Crossover Study in Single-Sided Deafness Comparing a Cartilage Conduction CROS System and an Air-Conduction CROS System.. Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 2024. DOI: 10.1097/mao.0000000000004199.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.