Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology · 2024
Long-Term Cochlear Implant Sound Processor Usage in Children with Single-Sided Deafness.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Garcia-Matte Raimundo J, O'Neil Luke M, Chase Carl, Leeming Pia, Clack Rachel, Rodrigues Steve, Kuthubutheen Jafri
Аннотация
OBJECTIVE: To assess cochlear implant (CI) sound processor usage over time in children with single-sided deafness (SSD) and identify factors influencing device use.
STUDY DESIGN: Retrospective, chart review study.
SETTING: Pediatric tertiary referral center.
PATIENTS: Children with SSD who received CI between 2014 and 2020.
OUTCOME MEASURE: Primary outcome was average daily CI sound processor usage over follow-up.
RESULTS: Fifteen children with SSD who underwent CI surgery were categorized based on age of diagnosis and surgery timing. Over an average of 4.3-year follow-up, patients averaged 4.6 hours/day of CI usage. Declining usage trends were noted over time, with the first 2 years postactivation showing higher rates. No significant usage differences emerged based on age, surgery timing, or hearing loss etiology.
CONCLUSIONS: Long-term usage decline necessitates further research into barriers and enablers for continued CI use in pediatric SSD cases.
STUDY DESIGN: Retrospective, chart review study.
SETTING: Pediatric tertiary referral center.
PATIENTS: Children with SSD who received CI between 2014 and 2020.
OUTCOME MEASURE: Primary outcome was average daily CI sound processor usage over follow-up.
RESULTS: Fifteen children with SSD who underwent CI surgery were categorized based on age of diagnosis and surgery timing. Over an average of 4.3-year follow-up, patients averaged 4.6 hours/day of CI usage. Declining usage trends were noted over time, with the first 2 years postactivation showing higher rates. No significant usage differences emerged based on age, surgery timing, or hearing loss etiology.