DOI 10.1016/j.knee.2021.03.014
Longitudinal study of knee load avoidant movement behavior after total knee arthroplasty with recommendations for future retraining interventions.
Аннотация
BACKGROUND
This study aimed to evaluate clinical and biomechanical changes in self-report survey, quadriceps strength and gait analysis over 3- and 6-months post-total knee arthroplasty (TKA) and confirm the immediate effects of two forms of kinetic biofeedback on improving inter-limb biomechanics during a physically demanding decline walking task.
METHODS
Thirty patients with unilateral TKA underwent testing at 3- and 6-months following surgery. All underwent self-report survey, quadriceps strength and gait analysis testing. Patients were assigned to one of two types of biofeedback [vertical ground reaction force (vGRF), knee extensor moment (KEM)].
RESULTS
No decrease in gait asymmetry was observed in non-biofeedback trials over time (p > 0.05), despite significant improvements in self-report physical function (p < 0.01, Cohen d = 0.44), pain interference (p = 0.01, Cohen d = 0.68), numeric knee pain (p = 0.01, Cohen d = 0.74) and quadriceps strength (p = 0.01, Cohen d = 0.49) outcomes. KEM biofeedback induced significant decrease in total support moment (p = 0.05, Cohen f2 = 0.14) and knee extensor moment (p = 0.05, Cohen f2 = 0.21) asymmetry compared to using vGRF biofeedback at 6-months. vGRF biofeedback demonstrated significant decrease in hip flexion kinematic asymmetry compared to KEM biofeedback (p = 0.05, Cohen f2 = 0.18) at 6-months.
CONCLUSION
Gait compensation remained similar from 3- to 6-months during a task requiring greater knee demand compared to overground walking post-TKA, despite improvements in self-report survey and quadriceps strength. Single session gait symmetry training at 6-month supports findings at 3-month testing that motor learning is possible. KEM biofeedback is more effective at immediately improving joint kinetic loading compared to vGRF biofeedback post-TKA.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.