Auditory Brainstem Implant Outcomes in Tumor and Nontumor Patients: A Systematic Review.
Аннотация
OBJECTIVE
To elucidate the differences in auditory performance between auditory brainstem implant (ABI) patients with tumor or nontumor etiologies.
DATA SOURCES: PubMed, Embase, and Web of Science Core Collection from 1990 to 2021.
REVIEW
METHODS
We included published studies with 5 or more pediatric or adult ABI users. Auditory outcomes and side effects were analyzed with weighted means for closed-set, open-set speech, and categories of auditory performance (CAP) scores. Overall performance was compared using an Adult Pediatric Ranked Order Speech Perception (APROSPER) scale created for this study.
RESULTS
Thirty-six studies were included and underwent full-text review. Data were extracted for 662 tumor and 267 nontumor patients. 83% were postlingually deafened and 17% were prelingually deafened. Studies that included tumor ABI patients had a weighted mean speech recognition of 39.2% (range: 19.6%-83.3%) for closed-set words, 23.4% (range: 17.2%-37.5%) for open-set words, 21.5% (range: 2.7%-48.4%) for open-set sentences, and 3.1 (range: 1.0-3.2) for CAP scores. Studies including nontumor ABI patients had a weighted mean speech recognition of 79.8% (range: 31.7%-84.4%) for closed-set words, 53.0% (range: 14.6%-72.5%) for open-set sentences, and 2.30 (range: 2.0-4.7) for CAP scores. Mean APROSPER results indicate better auditory performance among nontumor versus tumor patients (3.5 vs 3.0, P = .04). Differences in most common side effects were also observed between tumor and nontumor ABI patients.
CONCLUSION
Auditory performance is similar for tumor and nontumor patients for standardized auditory test scores. However, the APROSPER scale demonstrates better ABI performance for nontumor compared to tumor patients.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.