DOI 10.1097/mao.0000000000001796

Медицинская библиотека · Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology · 2018

A Comparison of Repeatability and Usability of Semi-Automated Volume Segmentation Tools for Measurement of Vestibular Schwannomas.

MacKeith Samuel A C, Das Tilak, Graves Martin, Patterson Andrew, Donnelly Neil, Mannion Richard, Axon Patrick, Tysome James

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

Semi-automated volume segmentation tools (SAVST) offer a less time consuming technique compared with manual volume segmentation method. No data exists to suggest which of the available applications are optimal for use with vestibular schwannomas (VS). This study aims to compare repeatability and usability of three different SAVST for measurement of VS.

STUDY

DESIGN

Experimental comparison of three SAVST.

SETTING

Tertiary skull base unit.

PATIENTS: Twenty-four patients with a unilateral VS imaged with T1-weighted Gadolinium enhanced MRI.

INTERVENTION: Repeated measurements made to determine intra and inter-observer agreement. This was repeated using three different SAVST.

MAIN OUTCOME MEASURES: 1) Intra- and inter-observer intraclass correlation coefficients (ICC), repeatability coefficients (RC), and relative smallest detectable differences (%SDD).2) Usability as determined by the mean number of steps and time required per tumor measurement and the proportion of cases where manual editing was required.

RESULTS

Intra-observer ICCs were significantly better for SliceOmatic and OleaSphere than AW VolumeShare (0.998 versus 0.994, p < 0.05). Inter-observer ICCs were also better for SliceOmatic (0.994) and OleaSphere (0.989) compared with AW VolumeShare (0.976), however, this was only significant for SliceOmatic (p = 0.012). SliceOmatic had a poorer usability profile requiring more manual editing, time, and individual steps per measurement but its "watershed segmentation" algorithm was better at measuring cystic or heterogenous tumors.

CONCLUSIONS

This is the first study to compare three SAVST for measurement of VS. While SliceOmatic had the highest repeatability, Olea Sphere combined comparable repeatability with improved usability and a greater degree of automation and was, therefore, deemed optimal for use in routine clinical practice.

Для цитирования: MacKeith Samuel A C, Das Tilak, Graves Martin, Patterson Andrew, Donnelly Neil, Mannion Richard, Axon Patrick, Tysome James. A Comparison of Repeatability and Usability of Semi-Automated Volume Segmentation Tools for Measurement of Vestibular Schwannomas.. Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 2018. DOI: 10.1097/mao.0000000000001796.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.