MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ophtha.2025.08.001

Медицинская библиотека · Ophthalmology · 2025

Spatio-Temporal Optical Phase Kit for Myopia Control: Stage 1 Results from a Randomized Controlled Clinical Trial in Chinese Children.

Fedtke Cathleen, Chen Zhi, Tilia Daniel, Li Lihua, Chen Xiaoqin, Ehrmann Klaus, Lahav-Yacouel Karen, Falk Darrin, Conrad Fabian, Tan Kah Ooi, Bakaraju Ravi C

СтатьяРандомизированное исследованиеМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: The Spatio-Temporal Optical Phase (S.T.O.P.; nthalmic Pty Ltd) kit provides a dynamic optical cue using optical films on single-vision spectacles. This study assessed the efficacy of 2 S.T.O.P. kits (kits 1 and 2) in reducing myopia progression against single-vision spectacles without optical films (control group).

DESIGN

Prospective, multi-site, parallel-group, double-masked randomized controlled trial.

PARTICIPANTS

One hundred fifty-five participants completed the study (n = 50, 52, and 53 in the kit 1, kit 2, and control groups, respectively).

METHODS

One hundred sixty eligible children 6 to 14 years of age with myopia of between -0.75 diopter (D) and -5.00 D and astigmatism of 1.50 D or less were enrolled at the Fudan University Eye and ENT Hospital and Tianjin Eye Hospital between December 2023 and February 2025. Participants were assigned randomly to wear kit 1, kit 2, or no optical films (control group). Axial length (AL) was measured at baseline, at dispensing, and at 1, 4, and 6 months after dispensing. Cycloplegic autorefraction was measured at baseline and 6 months after dispensing. Differences between the control and each test group for changes in AL and spherical-equivalent cycloplegic autorefraction were analyzed using linear mixed models in the intention-to-treat population. Differences in visual acuity (VA) and subjective ratings were also assessed.

MAIN OUTCOME MEASURES: Change in AL from dispensing to the 6-month visit and change in spherical-equivalent cycloplegic autorefraction from baseline to the 6-month visit.

RESULTS

After 6 months, both S.T.O.P. kit groups showed significantly less change in AL than the control group. The estimated least-square mean differences (95% confidence intervals) compared with control for AL were: kit 1, -0.091 (-0.131 to -0.051) mm and kit 2, -0.090 (-0.130 to -0.050) mm and for spherical-equivalent cycloplegic autorefraction were: kit 1, 0.135 (0.003 to 0.268) D and kit 2, 0.134 (0.001 to 0.267) D. No significant differences were found between groups for VA or any subjective rating.

CONCLUSIONS

Both S.T.O.P. kit groups showed significantly less myopia progression compared with the control group while maintaining good visual performance. The S.T.O.P. kit's dynamic approach represents a promising strategy for myopia management.

FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

Для цитирования: Fedtke Cathleen, Chen Zhi, Tilia Daniel, Li Lihua, Chen Xiaoqin, Ehrmann Klaus, Lahav-Yacouel Karen, Falk Darrin, Conrad Fabian, Tan Kah Ooi, Bakaraju Ravi C. Spatio-Temporal Optical Phase Kit for Myopia Control: Stage 1 Results from a Randomized Controlled Clinical Trial in Chinese Children.. Ophthalmology. 2025. DOI: 10.1016/j.ophtha.2025.08.001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.