Медицинская библиотека · Zhonghua gan zang bing za zhi = Zhonghua ganzangbing zazhi = Chinese journal of hepatology · 2006

[Observation on hybrid bioartificial liver support systems in treating chronic severe hepatitis: a study of 60 cases].

Luo Hong-tao, Liu Quan-mei, Tan Jia-ju, Ye Yi-nong, Zhang Pei-hua, Luo Zuan-di, Long Hui

Аннотация на английскомСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To study the clinical efficacy of three kinds of hybrid bioartificial liver support systems (HBLSS) in treating chronic severe hepatitis.

METHODS

A bioartificial liver support system (BAL), comprising porcine hepatocytes and fiber tube style bioreactor, was constructed. Then three kinds of HBLSS were constructed: Molecular absorbent recirculating system (MARS) plus BAL; slow plasma exchange (SPE) plus continuous hemodiafiltration (CHDF) and BAL; and SPE plus hemoperfusion (HP) and BAL. One hundred-twenty patients in middle or late stages of chronic severe hepatitis were enrolled in this study. They were randomly divided into 6 groups: H1 group was treated with BAL+MARS, H2 with BAL+SPE+CHDF and H3 with BAL+SPE+HP (as treatment groups); C1 group was treated with MARS, C2 with SPE+CHDF and C3 with SPE+HP (as control groups). The changes in the clinical symptoms, in the hepatic encephalopathy stages, and in the serum total bilirubin (TBIL), the serum albumin (ALB), the prothrombin activities (PTA), endotoxin, ammonia, creatinine and a-fetal protein (AFP) were all observed before the treatment, right after it and 72 hours later. The improving and curing rates and the rates of side effect occurrences in each group were observed.

RESULTS

In all 6 groups, the patients' clinical symptoms ameliorated; their TBIL, endotoxin and ammonia levels decreased (P<0.05), and their PTA and AFP levels lowered significantly (P<0.05). But in the H1, H2 and H3 groups they were more distinctive than in the control groups. In H1 and H2 groups creatinine and ammonia levels were decreased more significantly than in the H3 group (P<0.05). The improving and curing rates of each group were 65 % (13/20), 60% (12/20), 45% (9/20), 45% (9/20), 40% (8/20) and 20% (4/20) respectively. No serious side effects were observed during the treatment.

CONCLUSION

In treating middle and late stage chronic severe hepatitis, the measures used in H1, H2 and H3 are better than those in C1, C2 and C3. Furthermore, H1 and H2 treatments can ameliorate hepatic and renal functions, prevent the development of multiple organ dysfunction syndrome, and are better than those used in H3.

Для цитирования: Luo Hong-tao, Liu Quan-mei, Tan Jia-ju, Ye Yi-nong, Zhang Pei-hua, Luo Zuan-di, Long Hui. [Observation on hybrid bioartificial liver support systems in treating chronic severe hepatitis: a study of 60 cases].. Zhonghua gan zang bing za zhi = Zhonghua ganzangbing zazhi = Chinese journal of hepatology. 2006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.