MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/coa.14107

Медицинская библиотека · Clinical otolaryngology : official journal of ENT-UK ; official journal of Netherlands Society for Oto-Rhino-Laryngology & Cervico-Facial Surgery · 2023

Mobile audiometry for hearing threshold assessment: A systematic review and meta-analysis.

Oremule Babatunde, Abbas Jonathan, Saunders Gabrielle, Kluk Karolina, Isba Rachel, Bate Sebastian, Bruce Iain

МетаанализСистематический обзорСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

Technological advancements in mobile audiometry (MA) have enabled hearing assessment using tablets and smartphones. This systematic review (PROSPERO ID: CRD42021274761) aimed to identify MA options available to health providers, assess their accuracy in measuring hearing thresholds, and explore factors that might influence their accuracy.

DESIGN AND

SETTING

A systematic search of online databases including PubMed, Embase, Cochrane, Evidence Search and Dynamed was conducted on 13th December 2021, and repeated on 30th October 2022, using appropriate Medical Subject Headings (MeSH) terms. Eligible studies reported the use of MA to determine hearing thresholds and compared results to conventional pure-tone audiometry (CA). Studies investigating MA for hearing screening (i.e. reporting just pass/fail) were ineligible for inclusion. Two authors independently reviewed studies, extracted data, and assessed methodological quality and risk of bias using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool.

PARTICIPANTS

Adults and children, with and without diagnosis of hearing impairment.

MAIN OUTCOME MEASURES: A meta-analysis was performed to obtain the mean difference between thresholds measured using MA and CA in dB HL.

RESULTS

Searches returned 858 articles. After systematic review, 17 articles including 1032 participants were analysed. The most used software application was ShoeboxTM (6/17) followed by Hearing TestTM (3/17), then HearTestTM (2/17). Tablet computers were used in ten studies, smartphones in six, and a computer in one. The mean difference between MA and CA thresholds was 1.36 dB (95% CI, 0.07-2.66, p = 0.04). Significant differences between mobile audiometry (MA) and conventional audiometry (CA) thresholds were observed in thresholds measured at 500Hz, in children, when MA was conducted in a sound booth, and when MA was self-administered. However, these differences did not exceed the clinically significant threshold of 10 decibels (dB). Included studies exhibited high levels of heterogeneity, high risk of bias and low concerns about applicability.

CONCLUSIONS

MA compares favourably to CA in measuring hearing thresholds and has role in providing access to hearing assessment in situations where CA is not available or feasible. Future studies should prioritize the integration of pure-tone threshold assessment with additional tests, such as Speech Recognition and Digits-in-Noise, for a more rounded evaluation of hearing ability, assesses acceptability and feasibility, and the cost-effectiveness of MA in non-specialist settings.

Для цитирования: Oremule Babatunde, Abbas Jonathan, Saunders Gabrielle, Kluk Karolina, Isba Rachel, Bate Sebastian, Bruce Iain. Mobile audiometry for hearing threshold assessment: A systematic review and meta-analysis.. Clinical otolaryngology : official journal of ENT-UK ; official journal of Netherlands Society for Oto-Rhino-Laryngology & Cervico-Facial Surgery. 2023. DOI: 10.1111/coa.14107.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.