MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0291412

Медицинская библиотека · PloS one · 2023

AMTASTM and user-operated smartphone research application audiometry-An evaluation study.

Sørensen Chris Bang, Adams Thomas Bording, Pedersen Ellen Raben, Nielsen Jacob, Schmidt Jesper Hvass

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate two user-operated audiometry methods, the AMTASTM PC-based audiometry and a low-cost smartphone audiometry research application (R-App).

DESIGN

A repeated-measures within-subject study design was used to compare both user-operated methods to traditional manual audiometry and to evaluate test-retest reliability of each method.

STUDY SAMPLE: 58 subjects were recruited in the study of which 83 ears had normal hearing thresholds and 33 ears had hearing loss (pure-tone average > 25 dB HL). Average age of participants was 44.8 years, with an age range of 11-85.

RESULTS

Standard deviation of absolute differences ranged between 3.9-6.9 dB on AMTASTM and 4.5-6.8 dB on the R-App. The highest variability was found at the 8000 Hz frequency (R-App and AMTASTM test) and 3000 Hz frequency (AMTASTM retest). Evaluation of test-retest reliability of AMTASTM and R-App showed SD of absolute differences ranging between 3.5-5.8 dB and 3.1-5.0 dB, respectively. The mean threshold difference between test and retest was within ±1.5 dB on AMTASTM and ±1 dB on the R-App.

CONCLUSION

Accuracy of AMTASTM and the R-App was within acceptable limits for audiometry and comparable to traditional manual audiometry on all tested frequencies (250-8000 Hz). Evaluation of test-retest reliability showed acceptable variation on both AMTASTM and R-App. Both user-operated methods could be reliably performed in a quiet non-soundproofed environment.

Для цитирования: Sørensen Chris Bang, Adams Thomas Bording, Pedersen Ellen Raben, Nielsen Jacob, Schmidt Jesper Hvass. AMTASTM and user-operated smartphone research application audiometry-An evaluation study.. PloS one. 2023. DOI: 10.1371/journal.pone.0291412.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.