Heat generation and histological analysis of peri-implant bone cutting using piezoelectric surgery for implant removal: an in vitro study.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Saito Yoshiki, Tsukamoto Hiroki, Shimada Kiyoshi, Kondo Yusuke, Kiyomura Keiko, Nodai Tomotaka, Munemasa Takashi, Mukaibo Taro, Hosokawa Ryuji, Masaki Chihiro

Аннотация

PURPOSE: This study aimed to evaluate the safety of piezoelectric surgery for bone cutting during implant removal in terms of heat generation and histological changes.

METHODS: The bone model experiments involved titanium implants or non-metal dummy implants placed in bone models. Bone cutting using a piezoelectric surgery with irrigation was performed at distances of 0, 1, and 2 mm from the implant, and the temperature was recorded using a contact thermometer placed at the tip of the implant. Using procine mandible models, histological analysis was performed using hematoxylin and eosin-stained images to evaluate the risk of thermal injury.

RESULTS: When bone cutting was performed at distances of 0 mm from the implants continuously, a significantly greater temperature increase was observed with the titanium implants compared to the non-metal dummy implants. The increase in temperature decreased as the distance between the implant and the cutting position increased. Comparing the cutting patterns, a greater temperature increase was observed with continuous and 10 s intermittent cutting. In contrast, it was suppressed with intermittent cutting for 3 and 5 s. In the histological analysis with porcine mandibles, findings suggest that thermal injury was not observed in any of the samples.

CONCLUSIONS: No bone damage was observed in the histological analysis. In contrast, piezoelectric peri-implant bone cutting caused a significant increase in temperature, especially for continuous bone cutting during implant adjustments. However, intermittent cutting for 3 and 5 s significantly suppressed the temperature increase. The results suggest that shortening the continuous cutting time may be effective in preventing heat generation when using piezoelectric surgery for peri-implant bone cutting.