Mandibular Gonial Angle Measurement with Anatomical Precision in 3D Volume Rendered CT Images.

Özden Furkan Mehmet, Sivri İsmail, Çolak Tuncay

Письмо в редакциюПеревод пока не подготовлен

Аннотация

PURPOSE: This letter presents a novel, simple, and reproducible method for measuring the gonial angle using open-source imaging software, 3D Slicer. The main research question was whether a standardized three-dimensional (3D) approach could provide a practical and accurate alternative to traditional two-dimensional cephalometric techniques.

METHODS

High resolution head computed tomography (CT) scans were imported into 3D Slicer (version 5.6.2). The mandible was reconstructed in 3D using volume rendering module. Two three-point planes were defined: one tangential to the mandibular body's lower border and one to the ramus' posterior border. Their angle was calculated using a Python script within 3D Slicer.

RESULTS

The workflow enabled accurate and reproducible 3D gonial angle measurements, providing flexibility for real-time adjustment, repeated calculations, and enhanced anatomical accuracy over traditional methods.

CONCLUSION

This approach offers a practical, cost-free, and standardized technique with potential applications in orthognathic surgery planning, asymmetry studies, and anthropological analysis of mandible.

LEVEL OF EVIDENCE V: Opinions of expert anatomists. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

Для цитирования: Özden Furkan Mehmet, Sivri İsmail, Çolak Tuncay. Mandibular Gonial Angle Measurement with Anatomical Precision in 3D Volume Rendered CT Images.. Aesthetic plastic surgery. 2025. DOI: 10.1007/s00266-025-05485-5.