Evaluation of scleral-fixated intraocular lens position anomalies by anterior segment optical coherence tomography.
Аннотация
BACKGROUND/AIM: To measure the positions of scleral-fixated intraocular lenses (IOLs) using anterior segment optical coherence tomography (OCT) and to evaluate the influence of the position of scleral-fixated IOL on the quality of vision.
MATERIALS AND
METHODS
Twenty-six eyes of 26 patients were included in the study. The average age was 57.5 (11 to 78) years. Anterior segment images were taken using slit lamp optical coherence tomography (SL-OCT) and were used to evaluate the position of the IOL.
RESULTS
The average amounts of tilt and decentration were 2.25° ± 1.93° and 359.28 ± 194.70 µm, respectively. There was a positive and moderate relationship between tilt and astigmatism caused by the position of the IOL (P = 0.030). No relationship was detected between decentration and the astigmatism caused by the position of the IOL (P = 0.285).
CONCLUSION
Scleral-fixated IOL position can be evaluated with SL-OCT, which is a noncontact, noninvasive, reproducible, and reliable method of evaluation. Anterior segment OCT has been shown to provide sensitive measurements but not in all cases. The present study showed that a tilted scleral-fixated IOL behaved like a toric IOL, and the astigmatism caused by the position of the scleral-fixated IOL therefore could increase or decrease total astigmatism.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.