American journal of veterinary research · 2012
Refractive state following retinal reattachment and silicone oil tamponade in dogs.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Hoffman Allison, Wolfer Joe, Occelli Laurence, Lehenbauer Terry W, Sapienza John, Novak Jenny M, Combs Kelli L, Konrade Kricket A
Аннотация
OBJECTIVE: To evaluate the refractive error induced by intraocular administration of silicone oil (SiO) in dogs.
ANIMALS: 47 client-owned dogs evaluated for blindness secondary to retinal detachment.
PROCEDURES: -3-port pars plana vitrectomy with perfluoro-octane and SiO exchange (1,000- or 5,000-centistoke SiO) was performed in 1 or both eyes for all dogs (n = 63 eyes), depending on which eye or eyes were affected. Dogs were normotensive, had complete oil filling of the eyes, and were examined in a standing position for retinoscopic examination of both eyes (including healthy eyes).
RESULTS: The mean refractive error for SiO-filled phakic and pseudophakic eyes was 2.67 and 3.24 D, respectively. The mean refractive error for SiO-filled aphakic eyes was 6.50 D. Dogs in which 5,000-centistoke SiO was used had consistently greater positive refractive errors (mean, 3.45 D), compared with dogs in which 1,000-centistoke SiO was used (mean, 2.10 D); however, the difference was nonsignificant. There was no significant linear relationship between refractive error and the number of days between surgery and retinoscopy.
CONCLUSIONS AND CLINICAL RELEVANCE: Hyperopia was observed in all dogs that underwent SiO tamponade, regardless of lens status (phakic, pseudophakic, or aphakic). Aphakic eyes underwent a myopic shift when filled with SiO. Pseudophakic eyes appeared to be more hyperopic than phakic eyes when filled with SiO; however, additional investigation is needed to confirm the study findings.
ANIMALS: 47 client-owned dogs evaluated for blindness secondary to retinal detachment.
PROCEDURES: -3-port pars plana vitrectomy with perfluoro-octane and SiO exchange (1,000- or 5,000-centistoke SiO) was performed in 1 or both eyes for all dogs (n = 63 eyes), depending on which eye or eyes were affected. Dogs were normotensive, had complete oil filling of the eyes, and were examined in a standing position for retinoscopic examination of both eyes (including healthy eyes).
RESULTS: The mean refractive error for SiO-filled phakic and pseudophakic eyes was 2.67 and 3.24 D, respectively. The mean refractive error for SiO-filled aphakic eyes was 6.50 D. Dogs in which 5,000-centistoke SiO was used had consistently greater positive refractive errors (mean, 3.45 D), compared with dogs in which 1,000-centistoke SiO was used (mean, 2.10 D); however, the difference was nonsignificant. There was no significant linear relationship between refractive error and the number of days between surgery and retinoscopy.
CONCLUSIONS AND CLINICAL RELEVANCE: Hyperopia was observed in all dogs that underwent SiO tamponade, regardless of lens status (phakic, pseudophakic, or aphakic). Aphakic eyes underwent a myopic shift when filled with SiO. Pseudophakic eyes appeared to be more hyperopic than phakic eyes when filled with SiO; however, additional investigation is needed to confirm the study findings.