MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jaapos.2011.05.021

Медицинская библиотека · Journal of AAPOS : the official publication of the American Association for Pediatric Ophthalmology and Strabismus · 2011

Comparison of aphakic refraction formulas for secondary in-the-bag intraocular lens power estimation in children.

Abdel-Hafez Ghada, Trivedi Rupal H, Wilson M Edward, Bandyopadhyay Dipankar

Сравнительное исследованиеСтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: Intraocular lens (IOL) formulas based on aphakic refraction alone have been proposed as an alternative to biometry-based formulas. The purpose of this study was to determine the relative accuracy of these simplified formulas.

METHODS

Records of patients who received secondary in-the-bag (IOL) implants and for whom aphakic refraction was obtainable were retrospectively studied. The formulas for IOL power calculation by Hug (J Pediatr Ophthalmol Strabismus 2004;41;209-11) and Khan and by AlGaeed (Br J Ophthalmol 2006;90:1458-60; modified to account for greater K values in our population) were compared with the biometry-based Holladay 1 formula by calculating the absolute prediction error for each.

RESULTS

Twenty eyes met the inclusion criteria. The average age at IOL implantation was 4.8 ± 3.4 years. The mean of the absolute value of the prediction error when we used the Hug's formula was 2.4 ± 2.1 D; with Khan's formula, 2.4 ± 2.0 D; and with biometry, 1.6 ± 1.4 D. None of these differences was statistically significant (paired t test: Hug vs Khan, P = 0.9; biometry vs Hug, P = 0.3; biometry vs Khan, P = 0.2). The absolute prediction error was more than 2 D in 8 of 20 eyes (40%) when we used Hug's formula, 11 of 20 eyes (55%) with Khan's formula, and 5 of 20 eyes (25%) with biometry.

CONCLUSIONS

Although the 0.8 D reduction in accuracy of the refraction-based formulas was not statistically significant, we recommend continued use of biometry-based formulas for IOL power calculation. Aphakic refraction may be used to confirm IOL power prediction when biometry is difficult.

Для цитирования: Abdel-Hafez Ghada, Trivedi Rupal H, Wilson M Edward, Bandyopadhyay Dipankar. Comparison of aphakic refraction formulas for secondary in-the-bag intraocular lens power estimation in children.. Journal of AAPOS : the official publication of the American Association for Pediatric Ophthalmology and Strabismus. 2011. DOI: 10.1016/j.jaapos.2011.05.021.