Development of a 3D optical scanner for evaluating patient-specific dose distributions.

Chang Kyung Hwan, Lee Suk, Jung Hong, Choo Yeon-Wook, Cao Yuan Jie, Shim Jang Bo, Kim Kwang Hyeon, Lee Nam Kwon, Park Young Je, Kim Chul Yong, Cho Sam Ju, Lee Sang Hoon, Min Chul Kee, Kim Woo Chul, Cho Kwang Hwan, Huh Hyun Do, Lim Sangwook

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: This paper describes the hardware and software characteristics of a 3D optical scanner (P3DS) developed in-house. The P3DS consists of an LED light source, diffuse screen, step motor, CCD camera, and scanner management software with 3D reconstructed software.

MATERIALS AND METHOD: We performed optical simulation, 2D and 3D reconstruction image testing, and pre-clinical testing for the P3DS. We developed the optical scanner with three key characteristics in mind. First, we developed a continuous scanning method to expand possible clinical applications. Second, we manufactured a collimator to improve image quality by reducing scattering from the light source. Third, we developed an optical scanner with changeable camera positioning to enable acquisition of optimal images according to the size of the gel dosimeter.

RESULTS

We confirmed ray-tracing in P3DS with optic simulation and found that 2D projection and 3D reconstructed images were qualitatively similar to the phantom images. For pre-clinical tests, the dose distribution and profile showed good agreement among RTP, optical CT, and external beam radiotherapy film data for the axial and coronal views. The P3DS has shown that it can scan and reconstruct for evaluation of the gel dosimeter within 1 min. We confirmed that the P3DS system is a useful tool for the measurement of 3D dose distributions for 3D radiation therapy QA. Further experiments are needed to investigate quantitative analysis for 3D dose distribution.

Для цитирования: Chang Kyung Hwan, Lee Suk, Jung Hong, Choo Yeon-Wook, Cao Yuan Jie, Shim Jang Bo, Kim Kwang Hyeon, Lee Nam Kwon, Park Young Je, Kim Chul Yong, Cho Sam Ju, Lee Sang Hoon, Min Chul Kee, Kim Woo Chul, Cho Kwang Hwan, Huh Hyun Do, Lim Sangwook. Development of a 3D optical scanner for evaluating patient-specific dose distributions.. Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). 2015. DOI: 10.1016/j.ejmp.2015.05.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.