MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1590/s0102-76382008000400014

Медицинская библиотека · Revista brasileira de cirurgia cardiovascular : orgao oficial da Sociedade Brasileira de Cirurgia Cardiovascular · 2008

Aortic valve replacement with different types of prosthesis: are there differences in the outcomes during hospital phase?

Feguri Gibran Roder, Macruz Hugo, Bulhões Domingos, Neves Antônio, Castro Rodrigo Moreira, Fonseca Luciana da, Baungratz José Francisco, Silva José Pedro da

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To analyze intraoperative data and possible differences in clinical evolution during postoperative hospital phase for aortic valve replacement surgery using different types of prosthesis.

METHODS

Analysis of 60 patients divided into three groups. Valve replacement with bioprosthesis (20), mechanical prosthesis (20) and homologous valve (20). The mean age was 51.1, 60% were male and 40% female patients; 86.7 % were in NYHA II or III; 63.3% presented arterial hypertension and 18.3% had diabetes. Aetiology of valve disease was degenerative for 39%, rheumatic for 36% and endocarditis for 15%.

RESULTS

The hospital mortality was 5%; there were no differences in the incidence of septic or cardiogenic shock, acute renal failure, rhythms disorders during surgery or intensive care, neither for total time in intensive care and mechanical ventilation. However, there was statistical differences as regards the cardiopulmonary bypass total time (P=0.02) and the aortic clamping time (P<0.0001) unfavorable to homograft valve group. The ward admission time was greater for mechanical valve group (P=0.05) as well as for total admission time, but without statistical significance. It was observed that patients with preoperative hematocrit smaller than 38.1% used 2.73 units of blood components, and with postoperative hematocrit smaller than 32% used 1,79 units of blood components. Echocardiography control showed minimal evolutional differences.

CONCLUSION

The use of different types of prosthesis for this study does not cause differences in the results of postoperative hospital phase. The use of homograft valve is a feasible option with good clinical applicability.

Для цитирования: Feguri Gibran Roder, Macruz Hugo, Bulhões Domingos, Neves Antônio, Castro Rodrigo Moreira, Fonseca Luciana da, Baungratz José Francisco, Silva José Pedro da. Aortic valve replacement with different types of prosthesis: are there differences in the outcomes during hospital phase?. Revista brasileira de cirurgia cardiovascular : orgao oficial da Sociedade Brasileira de Cirurgia Cardiovascular. 2008. DOI: 10.1590/s0102-76382008000400014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.