DOI 10.1038/s41433-021-01524-y
Comparison of outflow facility before and after the microhook ab interno trabeculotomy.
Аннотация
PURPOSES: To elucidate the mechanism of intraocular pressure (IOP) reduction by microhook ab interno trabeculotomy (μLOT), the aqueous humour outflow facility was compared preoperatively and post-operatively.
METHODS
Fifty-one eyes (37 patients; mean age, 67.2 ± 11.8 years) were included. The IOP, number of medications and outflow facility coefficient (C) estimated by pneumatonography were compared preoperatively and post-operatively using the paired t test. Linear regression analysis was performed to identify possible correlations between the C value and IOP or number of medications. To adjust for biases from including both eyes of a patient and differences in background, the preoperative and post-operative C values were compared using a mixed effects regression model.
RESULTS
The mean preoperative IOP (18.2 mmHg) and mean number of medications (2.8) decreased significantly post-operatively by 26% and 18%, respectively, to 13.5 mmHg and 2.3 (p < 0.0001, for both comparisons). The preoperative C value of 0.27 µl/min/mmHg increased significantly (p < 0.0001) by 89% to 0.51 µl/min/mmHg post-operatively. Linear regression analysis indicated that higher IOP was associated with lower C values (estimate, -0.01/mmHg, p = 0.0107); medication numbers were not associated with the C value (estimate, -0.04/medication, p = 0.1739). Mixed effects regression analysis showed that the post-operative measurement (estimate, 0.11/preoperative measurement, p < 0.0001) was associated with a higher C value, while age, sex, µLOT procedure, IOP and medication numbers were not.
CONCLUSION
Outflow facility assessed by the tonographic C value increased significantly after µLOT. Increased conventional outflow by elimination of the outflow resistance at the trabecular meshwork is the main mechanism of IOP reduction after µLOT.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.