MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/jrr/rru027

Медицинская библиотека · Journal of radiation research · 2014

Validation of accuracy in image co-registration with computed tomography and magnetic resonance imaging in Gamma Knife radiosurgery.

Nakazawa Hisato, Mori Yoshimasa, Komori Masataka, Shibamoto Yuta, Tsugawa Takahiko, Kobayashi Tatsuya, Hashizume Chisa

Клиническое исследованиеСтатьяВалидационное исследованиеПеревод пока не подготовлен

Аннотация

The latest version of Leksell GammaPlan (LGP) is equipped with Digital Imaging and Communication in Medicine (DICOM) image-processing functions including image co-registration. Diagnostic magnetic resonance imaging (MRI) taken prior to Gamma Knife treatment is available for virtual treatment pre-planning. On the treatment day, actual dose planning is completed on stereotactic MRI or computed tomography (CT) (with a frame) after co-registration with the diagnostic MRI and in association with the virtual dose distributions. This study assesses the accuracy of image co-registration in a phantom study and evaluates its usefulness in clinical cases. Images of three kinds of phantoms and 11 patients are evaluated. In the phantom study, co-registration errors of the 3D coordinates were measured in overall stereotactic space and compared between stereotactic CT and diagnostic CT, stereotactic MRI and diagnostic MRI, stereotactic CT and diagnostic MRI, and stereotactic MRI and diagnostic MRI co-registered with stereotactic CT. In the clinical study, target contours were compared between stereotactic MRI and diagnostic MRI co-registered with stereotactic CT. The mean errors of coordinates between images were < 1 mm in all measurement areas in both the phantom and clinical patient studies. The co-registration function implemented in LGP has sufficient geometrical accuracy to assure appropriate dose planning in clinical use.

Для цитирования: Nakazawa Hisato, Mori Yoshimasa, Komori Masataka, Shibamoto Yuta, Tsugawa Takahiko, Kobayashi Tatsuya, Hashizume Chisa. Validation of accuracy in image co-registration with computed tomography and magnetic resonance imaging in Gamma Knife radiosurgery.. Journal of radiation research. 2014. DOI: 10.1093/jrr/rru027.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.