Large-area versus small-area application of mitomycin C during trabeculectomy.

Matlach Juliane, Panidou Ermioni, Grehn Franz, Klink Thomas

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To compare 2 different application methods of mitomycin C (MMC) in patients undergoing trabeculectomy.

METHODS

This retrospective trial compared outcomes of 191 eyes that underwent trabeculectomy with small-area (96 eyes; 50.3%) and large-area (95 eyes; 49.7%) MMC application. Main outcome measures were changes in intraocular pressure (IOP), required glaucoma medications, the frequency of complications, and postsurgical interventions.

RESULTS

Within both treatment groups, a highly significant IOP reduction was seen during follow-up (p < 0.0001). Statistical analyses revealed a significant difference in IOP between both groups. Patients treated with a larger size of surface area had a higher IOP reduction within the first postoperative year. Choroidal detachment, shallow anterior chamber, and bleb leak were seen more often in the large-area group with more aggressive MMC use. In contrast, complications associated with bleb failure such as bleb scarring were higher in the small-area group. Success rate was higher in the large-area MMC application group after 12 months.

CONCLUSIONS

Large-area treatment seems to be a more efficient application method of MMC during trabeculectomy.

Для цитирования: Matlach Juliane, Panidou Ermioni, Grehn Franz, Klink Thomas. Large-area versus small-area application of mitomycin C during trabeculectomy.. European journal of ophthalmology. 2013. DOI: 10.5301/ejo.5000287.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.