Supraciliochoroidal fluid at an early stage after trabeculectomy.

Sugimoto Kota, Ito Kunio, Esaki Koji, Miyamura Masataka, Sasoh Mikio, Uji Yukitaka

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To detect the presence of supraciliochoroidal fluid (SCF) by ultrasound biomicroscopy (UBM) at an early stage after trabeculectomy.

METHODS

Trabeculectomy with mitomycin C was performed on 14 patients (15 eyes) with medically uncontrolled glaucoma. The ciliary bodies were observed using UBM testing, which was conducted preoperatively and within 2 weeks after the procedure.

RESULTS

SCF was detected postoperatively in 6 eyes. One eye also had choroidal detachment (CD), as seen with an indirect ophthalmoscope; and 5 eyes (33%) had SCF without intraocular inflammatory clinical signs, postoperative changes of the anterior chamber depth, or obvious CD. The SCF in 4 eyes disappeared within 4 weeks after the trabeculectomy. The intraocular pressure (IOP) was 6.4 +/- 3.4 mm Hg (mean +/- SD) when SCF was detected and it rose to 13.2 +/- 7.2 mm Hg when the SCF disappeared. The IOP was 11.4 +/- 4.0 mm Hg in the eyes without SCF, which was significantly higher than that seen in the eyes with SCF.

CONCLUSIONS

At an early stage after trabeculectomy, SCF without subclinical CD was detected in some cases by UBM. Compared with the reported frequency of SCF after 3 or 6 months, our study revealed that SCF was present more frequently at an early stage after trabeculectomy. Our results may indicate that the presence of SCF is related to the early low IOP after trabeculectomy and that the disappearance of SCF induces the elevation of IOP.

Для цитирования: Sugimoto Kota, Ito Kunio, Esaki Koji, Miyamura Masataka, Sasoh Mikio, Uji Yukitaka. Supraciliochoroidal fluid at an early stage after trabeculectomy.. Japanese journal of ophthalmology. 2002. DOI: 10.1016/s0021-5155(02)00533-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.