MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/10255842.2020.1780427

Медицинская библиотека · Computer methods in biomechanics and biomedical engineering · 2020

A comparison between the mechanical properties of the hepatic round ligament and the portal vein: a clinical implication on surgical reconstruction of the portal and superior mesenteric veins.

Zhu Wentao, Song Rongqiang, Cao Xuefeng, Zhou Lei, Wei Qiang, Ji Haibin, Fu Rongzhan

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

Abdominal malignant tumors originated from cancers, such as vater ampulla carcinoma (VAC) and pancreatic cancer (PC), often invades the portal vein (PV) and the superior mesenteric vein (SMV) upon metastasis. Surgical removal of these tumors leads to sacrifice of parts of these vessels that need to be reconstructed with autograft tissues. Current options for the replacement tissue all have their limitations in certain aspects. Therefore, improved interstitial material for the reconstruction with better tissue compatibility is urgently needed. In the present study, we explored the potential of hepatic round ligament (HRL) as a candidate tissue for the task from the biomechanical point of view. We reveal that HRL and PV share similar geometrical parameters in terms of vascular cavity diameter and wall thickness. In addition, they also have similar elastic properties and tissue flexibility and intensity upon increased cavity pressure. Our study strongly supports HRL as potential replacement tissue for PV reconstruction in term of mechanical properties and encourages further biological studies to be performed on these two tissues for further verification.

Для цитирования: Zhu Wentao, Song Rongqiang, Cao Xuefeng, Zhou Lei, Wei Qiang, Ji Haibin, Fu Rongzhan. A comparison between the mechanical properties of the hepatic round ligament and the portal vein: a clinical implication on surgical reconstruction of the portal and superior mesenteric veins.. Computer methods in biomechanics and biomedical engineering. 2020. DOI: 10.1080/10255842.2020.1780427.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.