MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/0194599812459449

Медицинская библиотека · Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery · 2012

A spheroid weighted-axis converter of vestibular schwannoma size: maximum diameter and cisternal volume.

Prendes Brandon L, Groppo Eli R, Reynolds Catherine L, Parsa Andrew T, Cheung Steven W

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

To evaluate spheroid models of vestibular schwannoma (VS) size for bidirectional conversion of maximum diameter in the cistern and 3-dimensional volume.

STUDY

DESIGN

Methodological study.

SETTING

Academic tertiary referral center.

SUBJECTS AND

METHODS

Magnetic resonance imaging studies from 91 patients with VS from 2003 to 2011 were analyzed. Linear measurements defining meatal and cisternal components were extracted. Geometrically based conformal models of tumor volume were compared with measured tumor volume using a semiautomated computerized tracing method. Models were inverted to predict maximum axial cisternal length at the level of the internal auditory canal (IAC).

RESULTS

A spheroid-weighted axis converter (SWC) of VS size was identified by minimizing input measurement parameters while maximizing output prediction performance. Computation steps of tumor volumes were (1) meatal-measure tumor lengths along the IAC and at the porus acusticus and take the average of a cone and cylinder and (2) cisternal-measure maximum tumor length in the axial IAC plane, use the median major:minor axis ratio of 1.26:1 to estimate minor axis length, take the geometric mean of axial dimensions to estimate axis length in the coronal plane, and apply input lengths to a spheroid. Performance error of this SWC had interquartile ranges of 33% for volume and 2 to 3 mm for maximum cisternal length.

CONCLUSION

Reporting variability of VS tumor size has made it difficult to reconcile outcomes studies. We propose an accessible tool for bidirectional conversion of volumetric and linear indices of tumor size to unlock potential for meta-analyses of disparate data sets.

Для цитирования: Prendes Brandon L, Groppo Eli R, Reynolds Catherine L, Parsa Andrew T, Cheung Steven W. A spheroid weighted-axis converter of vestibular schwannoma size: maximum diameter and cisternal volume.. Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery. 2012. DOI: 10.1177/0194599812459449.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.