Cochlear and Vestibular Volumes in Inner Ear Malformations.

Breitsprecher Tabita M, Pscheidl Alexander, Bächinger David, Volkenstein Stefan, Dhanasingh Anandhan, Van Rompaey Vincent, Mlynski Robert, Dazert Stefan, Van de Heyning Paul, Langner Sönke, Roland Peter, Weiss Nora M

СтатьяПеревод пока не подготовлен

Аннотация

UNLABELLED: A "gold standard" for quantitatively diagnosing inner ear malformations (IEMs) and a consensus on normative measurements are lacking. Reference ranges and cutoff values of inner ear dimensions may add in distinguishing IEM types. This study evaluates the volumes of the cochlea and vestibular system in different types of IEM.

STUDY

DESIGN

Retrospective cohort.

SETTING

Tertiary academic center.

PATIENTS: High-resolution CT scans of 115 temporal bones (70 with IEM; cochlear hypoplasia [CH]; n = 19), incomplete partition (IP) Types I and III (n = 16), IP Type II with an enlarged vestibular aqueduct (Mondini malformation; n = 16), enlarged vestibular aqueduct syndrome (n = 19), and 45 controls.

INTERVENTIONS: Volumetry by software-based, semiautomatic segmentation, and 3D reconstruction.

MAIN OUTCOME MEASURES: Differences in volumes among IEM and between IEM types and controls; interrater reliability.

RESULTS

Compared with controls (mean volume, 78.0 mm3), only CH showed a significantly different cochlear volume (mean volume, 30.2 mm3; p < 0.0001) among all types of IEM. A cutoff value of 60 mm3 separated 100% of CH cases from controls. Compared with controls, significantly larger vestibular system volumes were found in Mondini malformation (mean difference, 22.9 mm3; p = 0.009) and IP (mean difference, 24.1 mm3; p = 0.005). In contrast, CH showed a significantly smaller vestibular system volume (mean difference, 41.1 mm3; p < 0.0001). A good interrater reliability was found for all three-dimensional measurements (ICC = 0.86-0.91).

CONCLUSION

Quantitative reference values for IEM obtained in this study were in line with existing qualitative diagnostic characteristics. A cutoff value less than 60 mm3 may indicate an abnormally small cochlea. Normal reference values for volumes of the cochlea and vestibular system may aid in diagnosing IEM.

Для цитирования: Breitsprecher Tabita M, Pscheidl Alexander, Bächinger David, Volkenstein Stefan, Dhanasingh Anandhan, Van Rompaey Vincent, Mlynski Robert, Dazert Stefan, Van de Heyning Paul, Langner Sönke, Roland Peter, Weiss Nora M. Cochlear and Vestibular Volumes in Inner Ear Malformations.. Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 2022. DOI: 10.1097/mao.0000000000003615.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.