PURPOSE: To elucidate the status of speech perception ability in cochlear implant wearers with unknown deafness causes.
MATERIALS AND
METHODS
We extracted 1095 patients between January 1, 1986, and December 31, 2019; among them, there were 418 first-surgery adults who wore implants made by Cochlear. Finally, we included 204 patients (69 males and 135 women) without cochlear morphological abnormalities. All electrodes were inserted into the cochlea, without major intraoperative and postoperative problems. The minimum, maximum, and average ages of surgery were 17 years, 85 years, and 56.5 years, respectively. The participants were divided according to the electrode (Group A, CI22 straight electrode; Group B, CI24 straight electrode; Group C, modiolar hugging electrode type electrode; and Group D, slim straight electrode). We evaluated the following parameters: cochlear implant threshold and single-syllable, word, and single-sentence hearing ability. Further, we investigated impactful background factors.
RESULTS
There was a decreased cochlear implant threshold in Groups B and C. Group B had a better ability to hear single syllables, words, and sentences than Group A. Groups C and D had significantly better ability to hear words than Group B. Low hearing aid threshold, good hearing ability with the 67S hearing aid, and short duration of hearing loss were associated with enhanced hearing ability.
CONCLUSION
In this study, it was suggested that the listening ability may have improved because of the progress of the electrodes. However, the possibility of a ceiling effect was also suggested.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.