Development and Validation of a Parenting Stress Module for Parents of Children Using Cochlear Implants.
Аннотация
OBJECTIVES
The purpose of this study was to develop and validate a cochlear implant (CI)-specific parenting stress measure using the FDA Guidance on Patient-Reported Outcomes (2009).
METHODS
The development and psychometric validation of the Parenting Stress-CI module for both the Early Childhood (EC; 0-5 years) and School-Age (SA; 6-12 years) versions are reported in this article. Instrument development consisted of qualitative interviews with parents of children with CIs (EC: N = 19; SA: N = 21), content analysis, item development, and cognitive testing of the instrument. Last, we conducted the psychometric validation (EC: N = 72; SA: N = 64), including analyses of internal consistency, test-retest reliability (∼2 weeks between administrations; N = 24), and convergent validity with the Parenting Stress Index-4 (PSI-4).
RESULTS
The final EC version includes 15 questions, and the SA version includes 8 questions. Both the EC and SA versions had strong reliability (EC α = .88; SA α = .85), with all items significantly correlated with the overall module (r = .43-.80). Both versions also had strong test-retest reliability (r = .99, p < .001). Last, analyses of convergent validity demonstrated significant correlations with the PSI-4 Total Stress scale for both Parenting Stress-CI versions (EC r = .66, p < .00; SA r = .45, p < .001).
CONCLUSIONS
The Parenting Stress-CI modules are reliable and valid condition-specific parenting stress instruments for parents of children with CIs ages 0-12 years, filling a significant gap in the literature. These fully validated instruments can be used to assess parental needs for support and guide the development of targeted, family centered interventions.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.