MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.wneu.2018.10.065

Медицинская библиотека · World neurosurgery · 2018

Flexible Fiber CO2 Laser in Microsurgical Treatment of Intraventricular Tumors: Usefulness and Limitations.

Policicchio Domenico, Dipellegrini Giosuè, Muggianu Giampiero, Pintus Adriana, Sgaramella Enrico, Veneziani Santonio Filippo, Boccaletti Riccardo

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To assess usefulness and limitations of flexible fiber carbon dioxide (CO2) laser in the microsurgical treatment of intraventricular tumors.

METHODS

We reviewed a series of 9 patients treated with microsurgical resection of intraventricular tumors using a flexible fiber CO2 laser. The lesions involved the third ventricle (8) and the frontal horn of the right lateral ventricle (1). Histology revealed 6 craniopharyngiomas, 1 pituitary macroadenoma, 1 subependymoma, and 1 neurocytoma. In all cases, an interhemispheric transcallosal approach was performed. The laser was used during callosotomy, fornix column sectioning, tumor debulking, and to facilitate tumor dissection. We used a 5-tiered score system to assess laser's efficacy in each surgical step (approach, dissection, debulking): grade 1: laser was not at all helpful, grade 5: laser was extremely helpful. Limits of the instrument also are discussed.

RESULTS

Gross total resection was achieved in 6 cases and subtotal resection in the remaining 3. Three patients had pulmonary complications treated without clinical sequelae. No laser-related complication was described. Mean utility score observed was 4.2 (range 3-5) during approach, 2.8 (range 2-4) during tumor dissection; and 3.3 (range 2-5) during tumor debulking. Main limits were low hemostatic effect and inefficiency versus calcified and highly vascularized tumors.

CONCLUSIONS

The CO2 laser proved to be a useful and safe tool that could be used for intraventricular pathology; its design is suitable for narrow surgical corridors like interhemispheric fissure and foramen of Monro; its main utility is the ability to create precise and relatively bloodless cut (callosotomy, tumor debulking); low hemostatic effect is its main limit.

Для цитирования: Policicchio Domenico, Dipellegrini Giosuè, Muggianu Giampiero, Pintus Adriana, Sgaramella Enrico, Veneziani Santonio Filippo, Boccaletti Riccardo. Flexible Fiber CO2 Laser in Microsurgical Treatment of Intraventricular Tumors: Usefulness and Limitations.. World neurosurgery. 2018. DOI: 10.1016/j.wneu.2018.10.065.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.