OBJECTIVES

The present study aimed to measure an association between the caloric test and vestibulo-ocular reflex gain and refixation saccades in individuals with auditory neuropathy spectrum disorders.

METHODS

Twenty individuals (9 males and 11 females), in the age range of 17 to 38 years, diagnosed with auditory neuropathy spectrum disorders, and 20 normal-hearing individuals (age and gender matched) participated in the study. All the individuals underwent case history, pure tone audiometry, immittance evaluation, otoacoustic emissions, auditory brainstem response, caloric tests and video head impulse tests.

RESULTS

All the patients with auditory neuropathy spectrum disorders in the present study had hypoactive caloric responses, which suggested peripheral vestibular lesions. The mean vestibulo-ocular reflex gain was reduced in few patients with auditory neuropathy, whereas few patients had normal vestibulo-ocular reflex gain.

CONCLUSIONS

The present study revealed a discrepancy between the caloric and video head impulse test results in auditory neuropathy spectrum disorders. The vestibular evaluation should be done for all patients with auditory neuropathy spectrum disorders to understand the various types of vestibular nerve lesions.

Для цитирования: Sinha Sujeet Kumar, Neupane Anuj Kumar, Gururaj Krithika. Dissociation between caloric test and the video head impulse test in individuals with auditory neuropathy spectrum disorders.. The Journal of laryngology and otology. 2024. DOI: 10.1017/s0022215124001099.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.