PURPOSE: This aimed to evaluate the prevalence and extent of bilateral sigmoid sinus dehiscence (SSD) and to explore the presence of idiopathic intracranial hypertension (IIH) in patients with unilateral pulsatile tinnitus (PT) with CTA/V.

METHODS

Sixty PT patients (52 females; 40.4 ± 11.6 years [20-72]) who underwent CTA/V and 30 non-PT patients (27 females; 38.4 ± 14.7 years [12-62]) were enrolled in this study. The primary outcome measure was the radiographic presence of SSD. The index of transverse sinus stenosis (ITSS) was obtained by multiplying the stenosis scale values for each transverse sinus, and once was ≥ 4, the presence of IIH was suspected.

RESULTS

The prevalence and extent of SSD on symptomatic side (78%; maximum transverse diameter, MTD 0.49 ± 0.23; maximum vertical diameter, MVD 0.50 ± 0.26 cm) were significantly higher and larger than those on asymptomatic side (50%, P < 0.001; MTD 0.35 ± 0.18, P = 0.006; MVD 0.30 ± 0.15 cm, P < 0.001) in the study group and those (20%, P < 0.001; MTD 0.36 ± 0.18, P = 0.073; MVD 0.30 ± 0.22 cm, P < 0.048) in the control group. The presence of SSD showed significant correlation with both PT (logistic regression analysis, OR 4.167 [1.450-11.97]; P = 0.008) and suspected IIH (OR 16.25 [1.893-139.5]; P = 0.011).

CONCLUSION

In PT patients, SSD has a significant correlation with PT and a potential correlation with IIH.

Для цитирования: Xu Shuaishuai, Ruan Shidong, Liu Shanfeng, Xu Jianrong, Gong Ruozhen. CTA/V detection of bilateral sigmoid sinus dehiscence and suspected idiopathic intracranial hypertension in unilateral pulsatile tinnitus.. Neuroradiology. 2018. DOI: 10.1007/s00234-018-1987-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.