MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3928/01913913-20180710-01

Медицинская библиотека · Journal of pediatric ophthalmology and strabismus · 2018

The Positive Predictive Value of Smartphone Photoscreening in Pediatric Practices.

Arnold Robert W, Arnold Andrew W, Hunt-Smith Taryn T, Grendahl Robin L, Winkle R Kevin

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To compare smartphone photoscreening with other commercial objective screeners for amblyopia screening for young children.

METHODS

Ten pediatricians in four practices employed Nokia 1020 smartphones (Espoo, Finland) with single-axis Gobiquity software (Scottsdale, AZ) during well-child visits. Outcomes of confirmatory pediatric ophthalmology examinations were prospectively compared using American Association for Pediatric Ophthalmology and Strabismus uniform standards.

RESULTS

Five percent of 6,310 in-office screenings were referred: 25% for high anisometropia, 31% for hyperopia, and 15% for myopia. The positive predictive value (PPV) in 217 follow-up examinations was 68% (95% confidence interval: 62% to 74%) by 2013 age-stratified standards and 77% (confidence interval: 71% to 83%) by 2003 American Association for Pediatric Ophthalmology and Strabismus standards. The follow-up rate was 65%.

CONCLUSIONS

Smartphone photoscreening had PPV comparable with other commercial objective screeners. Simple, valid photoscreeners should help pediatricians achieve widespread compliance with screening guidelines to reduce the burden of pediatric amblyopia vision impairment. [J Pediatr Ophthalmol Strabismus. 2018;55(6):393-396.].

Для цитирования: Arnold Robert W, Arnold Andrew W, Hunt-Smith Taryn T, Grendahl Robin L, Winkle R Kevin. The Positive Predictive Value of Smartphone Photoscreening in Pediatric Practices.. Journal of pediatric ophthalmology and strabismus. 2018. DOI: 10.3928/01913913-20180710-01.