m+Medelevator.RU
← Поиск публикаций
Journal of clinical microbiology · 2019

A Simple Microfluidic Assay for Diagnosing Tuberculous Meningitis in HIV-Uninfected Patients.

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Park Joung Ha, Jin Choong Eun, Koo Bonhan, Kwon Ji-Soo, Cha Hye Hee, Kim Ji Yeun, Noh Geun Su, Koo Yong Seo, Jeon Sang-Beom, Lee Sang-Ahm, Shin Yong, Kim Sung-Han

Аннотация

We evaluated the diagnostic performance of a simple and label-free pathogen enrichment method using homobifunctional imidoesters (HI) and a microfluidic system, called the SLIM assay, followed by real-time PCR from cerebrospinal fluid (CSF) in human immunodeficiency virus (HIV)-uninfected patients with suspected tuberculous meningitis (TBM). Patients with suspected TBM were prospectively enrolled in a tertiary hospital in an intermediate tuberculosis (TB)-burden country during a 30-month period. TBM was classified according to the uniform case definition. Definite and probable TBM were regarded as the reference standards for TBM, and possible TBM and not-TBM as the reference standards for not-TBM. Of 72 HIV-uninfected patients with suspected TBM, 10 were diagnosed with definite (n = 2) and probable (n = 8) TBM by the uniform case definition. The sensitivity of the SLIM assay was 100% (95% confidence interval [CI], 69 to 100%) compared with definite or probable TBM, and it was superior to those of mycobacterial culture (20% [95% CI, 3 to 56%]) and the Xpert MTB/RIF assay (0% [95% CI, 0 to 31%]). Of 21 possible TBM and 41 not-TBM patients by the uniform case definition, 5 possible TBM and no not-TBM patients gave positive results in the SLIM assay. The specificity of the SLIM assay was 92% (95% CI, 82 to 97%; 5/62). We demonstrated that the SLIM assay had a very high sensitivity and specificity with small samples of 10 cases of definite or probable TBM. Further studies are needed to confirm this finding and to compare the SLIM assay with mycobacterial culture, Xpert MTB/RIF, and Xpert MTB/RIF Ultra assays in a larger prospective cohort of patients with suspected TBM, including both HIV-infected and HIV-uninfected cases.

Предметные рубрики MeSH