MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/opo.12244

Медицинская библиотека · Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists) · 2015

Age and the amplitude of accommodation measured using dynamic retinoscopy.

León Alejandro, Estrada Jorge M, Rosenfield Mark

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: Dynamic retinoscopy (DR) is a procedure for assessing the accommodative response using a standard clinical instrument. The present study compared measurements of the amplitude of accommodation (AA) obtained using this technique with two subjective methods (modified push-down and minus lens). Additionally, the expected ranges for AA when measured by DR were determined.

METHOD: AA was measured in 1298 subjects between 5 and 60 years of age using the three techniques described above. Subjects were grouped into 5-year bins, and a descriptive univariate analysis of the data performed. Goodness-of fit plots were constructed to examine the overall model fit. Centile curves were calculated from the final model.

RESULTS

Mean values of AA obtained using DR were significantly lower than for the two subjective techniques. For the DR findings, no significant change was observed between 5 and 19 years of age (mean AA = 8.3 D) and between 45 and 60 years of age (mean AA = 0.6 D). AA values as a function of age were best fit by the polynomial regression equation: logAA = 1.93 + 0.49(age) - 0.19(age)(2) .

CONCLUSION

Measurements of AA determined using DR are significantly lower than the normative subjective findings published previously. This difference is at least partly due to the depth-of-field of the eye. These norms markedly overestimate accommodative responsivity. DR provides a simple technique for quantifying accommodation in the clinical setting.

Для цитирования: León Alejandro, Estrada Jorge M, Rosenfield Mark. Age and the amplitude of accommodation measured using dynamic retinoscopy.. Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists). 2015. DOI: 10.1111/opo.12244.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.