MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jbm.a.35535

Медицинская библиотека · Journal of biomedical materials research. Part A · 2015

Tissue performance of bladder following stretched electrospun silk fibroin matrix and bladder acellular matrix implantation in a rabbit model.

Huang Jian-Wen, Xu Yue-Min, Li Zhao-Bo, Murphy Sean V, Zhao Weixin, Liu Qiang-Qiang, Zhu Wei-Dong, Fu Qiang, Zhang Yao-Peng, Song Lu-Jie

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

The goal of this study was to investigate the tissue performance of bladder following stretched electrospun silk fibroin matrix (SESFM) implantation compared with bladder acellular matrix (BAM). We compared SESFM with BAM based on porosity and pore size. Scaffolds were separately transplanted into opposite walls of the bladder of 30 rabbits after stripping the bladder mucosa and smooth muscle (1.5 × 2.0 cm(2)). Gross anatomical observation, histological analysis and muscle contractility studies were performed at 2, 4, and 8 weeks post-op. SESFM has higher porosity and larger pore size compared with BAM (p < 0.05). At 2 weeks, the presence of vesical calculus was evident in 7/10 rabbits. Histological analysis showed that SESFM and BAM promoted similar degree of urothelium regeneration (p > 0.05). However, SESFM promoted a higher degree of smooth muscle and vessel regeneration compared to BAM (p < 0.05). In addition, muscle strips supported by SESFM displayed higher contractile responses to carbachol, KCl, and phenylephrine compared with BAM. At 8 weeks, both matrices elicited similar mild acute and chronic inflammatory reactions. Our results demonstrated that SESFM has greater ability to promote bladder tissue regeneration with structural and functional properties compared to BAM, and with similar biocompatibility.

Для цитирования: Huang Jian-Wen, Xu Yue-Min, Li Zhao-Bo, Murphy Sean V, Zhao Weixin, Liu Qiang-Qiang, Zhu Wei-Dong, Fu Qiang, Zhang Yao-Peng, Song Lu-Jie. Tissue performance of bladder following stretched electrospun silk fibroin matrix and bladder acellular matrix implantation in a rabbit model.. Journal of biomedical materials research. Part A. 2015. DOI: 10.1002/jbm.a.35535.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.