MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5603/ait.2017.0030

Медицинская библиотека · Anaesthesiology intensive therapy · 2017

Global end-diastolic volume could be more appropiate to reduce intraoperative bleeding than central venous pressure during major liver transection.

Redondo Francisco Javier, Padilla Dawid, Villazala Ruben, Villaeiro Pedro, Baladron Victor, Bejerano Natalia

Сравнительное исследованиеКонтролируемое клиническое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Central venous pressure often fails to identify the true value of cardiac preload. Our purpose is to investigate whether Global End-Diastolic Volume (GEDV) values can control hemodynamic parameters for the measurement of fluid volume, cardiac preload and blood loss during liver transection.

METHODS

This was a prospective clinical study that included patients undergoing liver resection. All patients were monitored by means of PiCCO technology and 222 hemodynamic measurements were performed in 74 patients. Fluid restriction was used. Transpulmonary thermodilutions were performed at different times of surgery, namely: 1. at the beginning of surgery; 2. before hepatectomy and after selective vascular exclusion (Time 1); 3. approximately half way through the liver transection (Time 2); and 4. after liver resection (Time 3).

RESULTS

One hundred and twenty-nine of the 222 GEDV values were decreased (prevalence of hypovolemia of 58.1%). However, twenty two of the 222 CVP values were decreased (prevalence of 10.8%). Sensitivity of CVP with regard to volume depletion (GEDV > 650 mL m-2) on the times (1, 2 and 3) were 16.28 (4.08-28.48, 95% CI), 18.18 (5.65-30.75, 95% CI) and 21.43 (7.83-35.03, 95% CI), respectively. There was no correlation between CVP and GEDV.

CONCLUSIONS

GEDV values may be more appropriate for monitoring cardiac preload during liver transection.

Для цитирования: Redondo Francisco Javier, Padilla Dawid, Villazala Ruben, Villaeiro Pedro, Baladron Victor, Bejerano Natalia. Global end-diastolic volume could be more appropiate to reduce intraoperative bleeding than central venous pressure during major liver transection.. Anaesthesiology intensive therapy. 2017. DOI: 10.5603/ait.2017.0030.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.