Mobilise-D insights to estimate real-world walking speed in multiple conditions with a wearable device.

Kirk Cameron, Küderle Arne, Micó-Amigo M Encarna, Bonci Tecla, Paraschiv-Ionescu Anisoara, Ullrich Martin, Soltani Abolfazl, Gazit Eran, Salis Francesca, Alcock Lisa, Aminian Kamiar, Becker Clemens, Bertuletti Stefano, Brown Philip, Buckley Ellen, Cantu Alma, Carsin Anne-Elie, Caruso Marco, Caulfield Brian, Cereatti Andrea, Chiari Lorenzo, D'Ascanio Ilaria, Garcia-Aymerich Judith, Hansen Clint, Hausdorff Jeffrey M, Hiden Hugo, Hume Emily, Keogh Alison, Kluge Felix, Koch Sarah, Maetzler Walter, Megaritis Dimitrios, Mueller Arne, Niessen Martijn, Palmerini Luca, Schwickert Lars, Scott Kirsty, Sharrack Basil, Sillén Henrik, Singleton David, Vereijken Beatrix, Vogiatzis Ioannis, Yarnall Alison J, Rochester Lynn, Mazzà Claudia, Eskofier Bjoern M, Del Din Silvia, Mobilise-D consortium

СтатьяПеревод пока не подготовлен

Аннотация

This study aimed to validate a wearable device's walking speed estimation pipeline, considering complexity, speed, and walking bout duration. The goal was to provide recommendations on the use of wearable devices for real-world mobility analysis. Participants with Parkinson's Disease, Multiple Sclerosis, Proximal Femoral Fracture, Chronic Obstructive Pulmonary Disease, Congestive Heart Failure, and healthy older adults (n = 97) were monitored in the laboratory and the real-world (2.5 h), using a lower back wearable device. Two walking speed estimation pipelines were validated across 4408/1298 (2.5 h/laboratory) detected walking bouts, compared to 4620/1365 bouts detected by a multi-sensor reference system. In the laboratory, the mean absolute error (MAE) and mean relative error (MRE) for walking speed estimation ranged from 0.06 to 0.12 m/s and - 2.1 to 14.4%, with ICCs (Intraclass correlation coefficients) between good (0.79) and excellent (0.91). Real-world MAE ranged from 0.09 to 0.13, MARE from 1.3 to 22.7%, with ICCs indicating moderate (0.57) to good (0.88) agreement. Lower errors were observed for cohorts without major gait impairments, less complex tasks, and longer walking bouts. The analytical pipelines demonstrated moderate to good accuracy in estimating walking speed. Accuracy depended on confounding factors, emphasizing the need for robust technical validation before clinical application.Trial registration: ISRCTN - 12246987.

Для цитирования: Kirk Cameron, Küderle Arne, Micó-Amigo M Encarna, Bonci Tecla, Paraschiv-Ionescu Anisoara, Ullrich Martin, Soltani Abolfazl, Gazit Eran, Salis Francesca, Alcock Lisa, Aminian Kamiar, Becker Clemens, Bertuletti Stefano, Brown Philip, Buckley Ellen, Cantu Alma, Carsin Anne-Elie, Caruso Marco, Caulfield Brian, Cereatti Andrea, Chiari Lorenzo, D'Ascanio Ilaria, Garcia-Aymerich Judith, Hansen Clint, Hausdorff Jeffrey M, Hiden Hugo, Hume Emily, Keogh Alison, Kluge Felix, Koch Sarah, Maetzler Walter, Megaritis Dimitrios, Mueller Arne, Niessen Martijn, Palmerini Luca, Schwickert Lars, Scott Kirsty, Sharrack Basil, Sillén Henrik, Singleton David, Vereijken Beatrix, Vogiatzis Ioannis, Yarnall Alison J, Rochester Lynn, Mazzà Claudia, Eskofier Bjoern M, Del Din Silvia, Mobilise-D consortium. Mobilise-D insights to estimate real-world walking speed in multiple conditions with a wearable device.. Scientific reports. 2024. DOI: 10.1038/s41598-024-51766-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.