MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ejrad.2014.12.024

Медицинская библиотека · European journal of radiology · 2015

Sigmoid plate dehiscence: congenital or acquired condition?

Liu Zhaohui, Li Jing, Zhao Pengfei, Lv Han, Dong Cheng, Liu Wenjuan, Wang Zhenchang

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND AND PURPOSE: The imaging features of sigmoid plate dehiscence-induced pulsatile tinnitus have been presented. The origin of the sigmoid plate dehiscence, however, remains unclear. Our aim was to assess the prevalence and extent of sigmoid plate dehiscence on computed tomography (CT) images in multiple age groups to determine whether this condition is more likely to be congenital or acquired.

MATERIALS AND

METHODS

We retrospectively reviewed contrast-enhanced CT images of sigmoid plates of temporal bones in 504 patients. Each temporal bone was characterized as normal or dehiscent. Patients were then subcategorized into four age groups, and the prevalence and extent of dehiscent sigmoid plates in each group were calculated and compared.

RESULTS

Overall, 80 patients had sigmoid plate dehiscence, nine of whom had it bilaterally. In successively older age groups, the prevalences of sigmoid plate dehiscence were 18.9%, 20.1%, 14.5%, and 12.7%, respectively. Respective average anteroposterior bony defect diameters were 3.7±1.7, 3.0±1.3, 3.1±1.5, and 3.0±1.1 mm. Respective average vertical bony defect diameters were 3.6±2.3, 2.6±1.2, 3.2±1.5, and 3.0±1.7 mm. The prevalence and extent of sigmoid plate dehiscence were not statistically different among the four age groups.

CONCLUSIONS

The similar radiologic prevalence and extent of dehiscent sigmoid plates among the age groups suggest that the dehiscence is more commonly a congenital than an acquired condition.

Для цитирования: Liu Zhaohui, Li Jing, Zhao Pengfei, Lv Han, Dong Cheng, Liu Wenjuan, Wang Zhenchang. Sigmoid plate dehiscence: congenital or acquired condition?. European journal of radiology. 2015. DOI: 10.1016/j.ejrad.2014.12.024.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.