MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/112067210701700505

Медицинская библиотека · European journal of ophthalmology · 2007

Intrascleral-fixated intraocular lenses for aphakic correction in the absence of capsular support.

Aznabayev R A, Zaidullin I S, Absalyamov M S H

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To present results of experience with the authors" technique for intrascleral fixation of intraocular lenses for the correction of aphakia in the absence of capsular support.

METHODS

Eleven patients (four children and seven adults) underwent surgery with the use of the method proposed by the authors (11 operations). The patients ranged in age from 11 to 75 years. The equatorial remnants in the lower segment of the capsular bag were revealed in 5 patients (45.5%). Absence of the capsular bag was observed in 6 patients (54.5%).

RESULTS

During long-term follow-up evaluation, visual acuity without correction (mean 0.33+/-0.05) corresponded to the preoperative corrected one. Better visual acuity outcome of 0.41+/-0.06 was achieved with added correction. With intrascleral fixation, a mean refractive error of 1.48+/-0.39 D should be taken into account when calculating intraocular lens power with use of the SRK II formula.

CONCLUSIONS

The results indicate that posterior chamber intraocular lens implantation with intrascleral fixation of haptics is a safe and effective technique for aphakic correction in the absence of capsular support and the presence of its defects. The technique used in the present study offers safety and stability of the intraocular lens position.

Для цитирования: Aznabayev R A, Zaidullin I S, Absalyamov M S H. Intrascleral-fixated intraocular lenses for aphakic correction in the absence of capsular support.. European journal of ophthalmology. 2007. DOI: 10.1177/112067210701700505.