The British journal of ophthalmology · 2006
Retinoscopic (refractive) estimation of axial length in paediatric aphakia: a comparison with ultrasonic measurement.
Сравнительное исследованиеОценочное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Khan A O
Аннотация
AIM: To compare paediatric axial length values estimated from the aphakic refraction alone with axial length values measured by ultrasound.
METHODS: Retrospective institutional medical record review of paediatric aphakic patients 12 years of age and younger with documented ultrasonic axial length and objective refraction (retinoscopy) within 3 months of each other. An estimate of axial length was made from the aphakic refraction alone (with an assumed average keratometry value of 44 dioptres) for all patients.
RESULTS: 149 eyes of 102 paediatric aphakic patients were identified. The ultrasonic axial length values (mean 22.47 mm, SD 1.69, 95% confidence interval (CI) 0.27) and estimated axial length values (mean 22.41 mm, SD 1.53, 95% CI 0.25) had an average difference of 0.05 mm (SD 1.04, 95% CI 0.17) and were not significantly different (p = 0.56) by the two tailed paired t test. A histogram of the differences that did exist between the two values resembled a normal distribution. The nine eyes with the largest differences between the two values had either low hyperopic aphakic refractions or abnormal average keratometry values.
CONCLUSIONS: There was no significant difference between the two groups of axial length values, and the distribution of differences that did exist seemed random. The greatest differences between the two values occurred in longer (less hyperopic) eyes and in eyes with abnormally steep or flat keratometry. Estimation of axial length from the aphakic refraction alone seems to be a useful technique in the average paediatric eye, especially if biometry is unavailable.
METHODS: Retrospective institutional medical record review of paediatric aphakic patients 12 years of age and younger with documented ultrasonic axial length and objective refraction (retinoscopy) within 3 months of each other. An estimate of axial length was made from the aphakic refraction alone (with an assumed average keratometry value of 44 dioptres) for all patients.
RESULTS: 149 eyes of 102 paediatric aphakic patients were identified. The ultrasonic axial length values (mean 22.47 mm, SD 1.69, 95% confidence interval (CI) 0.27) and estimated axial length values (mean 22.41 mm, SD 1.53, 95% CI 0.25) had an average difference of 0.05 mm (SD 1.04, 95% CI 0.17) and were not significantly different (p = 0.56) by the two tailed paired t test. A histogram of the differences that did exist between the two values resembled a normal distribution. The nine eyes with the largest differences between the two values had either low hyperopic aphakic refractions or abnormal average keratometry values.
CONCLUSIONS: There was no significant difference between the two groups of axial length values, and the distribution of differences that did exist seemed random. The greatest differences between the two values occurred in longer (less hyperopic) eyes and in eyes with abnormally steep or flat keratometry. Estimation of axial length from the aphakic refraction alone seems to be a useful technique in the average paediatric eye, especially if biometry is unavailable.